INSTALLATION GUIDE
PAGE
19
COMBO CLAMP INSTALLATION
INSTALL COMBO (MID) CLAMPS:
Clamp assemblies may be positioned in rail near
point of use prior to module placement.
Note: The clamps may be installed above splice
locations.
PLACE ADJACENT MODULE AGAINST
CLAMPS:
Modules must be tight against clamps
with no gaps. Tighten bolt to required
torque.
TORQUE VALUE: 15 ft-lbs.
INSTALL REMAINING MODULES:
Proceed with module installation. Engage each clamp
with previously positioned module.
INSTALL COMBO (END) CLAMPS:
Install Combo Clamps starting at the aligned end of
rails.
INSERT COMBO CLAMP:
Insert Combo Clamp from one side of
the rail nut into the rail and click in
the other side. Ensure that the rail nut
profile is seated in the rail profile.
INSTALL END MODULE:
Position first module onto rails
and engage module frame with end clamps. Hold clamp
in place against module while tightening bolt.
TORQUE VALUE: 15 ft-lbs.
Note: Ensure a minimum distance of 1” from the end of
the module to end of rail.
1/2"
1" min
PRO TIP
Press the clamp assembly slightly into the rail to
Press the clamp assembly slightly into the rail to
allow for easy sliding of clamp in the rail.
allow for easy sliding of clamp in the rail.