6-10-5.
Communication format
- Read gross weight (sign, 5-digit weight, decimal point)
- Read net weight (sign, 5-digit weight, decimal point)
- Read tare weight (sign, 5-digit weight, decimal point)
- Status 1 (7 digits)
- Status 2 (7 digits)
Host
F701+
R A
+
1 0 0
0 0
.
CR LF
R
CR
A
Host
F701+
R B
+
1 0 0
0 0
.
CR LF
R
CR
B
Host
F701+
R C
+
1 0 0
0 0
.
CR LF
R
CR
C
Host
F701+
R
CR
R D
0
0 0
0
CR
0
LF
D
0
0
1: ON
0: OFF
Tare subtraction
1: ON
0: OFF
Weight value stable
0: OFF
1: ON
Weight value HOLD
1: ON
0: OFF
1: Net weight
0: Gross weight
Weight display
1: OFF
1: ON
Weight value zero error
Undefined
Rear terminal LOCK
Host
F701+
R
CR
R E
0
0 0
0
CR
0
LF
E
0
0
1: ON
0: OFF
Under output signal
1: ON
0: OFF
SP3 signal
0: OFF
1: ON
SP1 signal
1: ON
0: OFF
1: ON
0: OFF
Go output signal
0: OFF
1: ON
SP2 signal
Over output signal
1: ON
0: OFF
Complete output signal