Key Operation
14
K
ey
O
pe
ra
tio
n
Chapter
2
2-2.
How to use the keys
■
How to use the setting keys
(Function key)
This function key is used to switch between setting modes.
(Numeric keys)
These are used to change the settings.
■
How to use the one-touch keys
(One-touch keys)
Press these keys while the weight is displayed to switch directly to the corresponding
setting mode 0.
(Numeric zero key)
Press this key to display one-touch tare subtraction weight. "
" will flash. (If tare
weight display is enabled using the Measurement Act compliance key in setting
mode 4-9.) Press the key again to display the accumulated value (the same as in
setting mode 8-9). Press the key again to return to weight display.
■
How to use the designated keys
(ZERO key)
The gross weight immediately becomes zero if this key is pressed.
A zero error will occur and the "
" will flash if this operation is performed while
the DZ regulation value is exceeded.
(GROSS/NET key)
Switch between gross weight and net weight is performed immediately if this key is
pressed while the weight value is displayed.
Net weight display appears if this key is pressed during gross weight display ("
"
lights up). Gross weight display appears if this key is pressed during net weight
display (" " lights up).
(CNG/ENT key)
Item change is started during setting item display, and setting item is confirmed
during item change.
(TARE key)
Tare subtraction is performed immediately and the net weight becomes zero if this
key is pressed. "
" lights up at the same time.
(TARE RESET key)
This key is used to reset tare subtraction. However, tare weight by digital tare
subtraction (preset tare subtraction) is not released.
Setting item keys in setting mode 0
1
2
3
4
5
6
7
8
9
Upper limit Lower limit Near zero Set point 1 Set point 2 Compensa-
tion
Over
Under
Final
to
to
[Weight display]
[Tare subtraction weight]*
[Accumulated value]
* When the tare subtraction display is invalid, the display switches directly to
[accumulated value] without displaying the [tare subtraction weight].