![Unipulse F701+ Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/unipulse/f701/f701_operation-manual_843485062.webp)
55
5
Timing Chart for Weighing
55
Ti
m
in
g
C
ha
rt
fo
r W
ei
gh
in
g
Chapter
5
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
No.
Sequence control operation
Checking status
display
Keys for relevant settings
External input signal
to be used
External output
signal to be used
1
Waiting for start signal input
SP1/SP2/SP3 blinks
SP1/SP2/SP3 blinks at medium speed
2
Execution of tare subtraction
Tare lights up
Setting mode 2-1:
final and over/under comparison
Tare subtraction
(5 pin)
Sets the compared weight value to zero (In the chart, tare subtraction is executed by external input and the NET weight is set to zero.)
3
Start signal ON is input
SP1/SP2/SP3
lights up
Setting mode 5-1: input selection
Start (input selection)
Set point 1 (7 pin) ON
Set point 2 (8 pin) ON
Set point 3 (9 pin) ON
4
Input of pause signal ON and
waiting for restart
SP1/SP2/SP3
blinks
Setting mode 5-1: input selection
Setting mode 5-2: output selection
Pause (input selec-
tion)
Set point 1 (7 pin) OFF
Set point 2 (8 pin) OFF
Set point 3 (9 pin) OFF
Output selection:
paused (23 pin) ON
* 1
When the pause signal ON is input, status switches to paused, paused status output turns ON, and set point 1/set point 2/set point 3 turns
OFF.
SP1/SP2/SP3 blinks at low speed
5
Start signal ON input and the
control status after restarting
SP2/SP3 lights up
SP1 goes out
Setting mode 5-1: input selection
Setting mode 5-2: output selection
Setting mode 5-3:
restart setting set point 1
Start (input selection)
Set point 1 (7 pin) ON
Set point 2 (8 pin) ON
Set point 3 (9 pin) ON
Output selection:
paused (23 pin) OFF
* 2 During paused status, the operation is restarted when start signal ON is input.
When restarting, returns to the last control output status, after confirming stability.
* 3
The following restrictions apply to each of the control output status when restarting
- Restored with OFF if previous status was OFF
- Set point 1 output is OFF when weight value at restart
>
(final - set point 1) × restart setting set point 1 when set point 1 is ON.
* 4 Set point 1 output is OFF when compared weight value
≧
final setting value - set point 1 setting value
* In the chart, the OFF condition is met through set point 1 of restart setting.
6
Final - set point 2
≦
net weight
value
SP2 goes out
Setting mode 0-5: set point 2
Setting mode 0-9: final
Setting mode 2-1:
final and over/under comparison
Set point 2 (8 pin)
OFF
* 5 Set point 2 output is OFF when compared weight value
≧
final setting value - set point 2 setting value
7
Operation of the comparison
inhibit timer
Setting mode 1-8:
comparison inhibit time (t1)
8
Final - compensation
≦
net
weight
SP3 goes out
Setting mode 0-6: compensation
Setting mode 0-9: final
Setting mode 2-1:
final and over/under comparison
Set point 3 (9 pin)
OFF
* 6 Set point 3 output is OFF when compared weight value
≧
final setting value - compensation setting value
9
Operation of the judging timer
Setting mode 1-2: judging time (t2)
10
Output of complete signal and
output of judging signal
HOLD lights up
HI, GO or LO lights
up
Setting mode 0-7: over
Setting mode 0-8: under
Setting mode 0-9: final
Setting mode 1-3:
complete output time (t3)
Setting mode 2-1:
final and over/under comparison
Setting mode 2-2:
output selection (22 pin)
Setting mode 2-2:
complete signal output mode
Over (10 pin) ON
Under (11 pin) ON
Output selection: GO
(22 pin) ON
Output selection:
complete (22 pin) ON
* 7
Under is ON when compared weight value
<
final setting value - under setting value
Over is ON when compared weight value
>
final setting value + over setting value
GO is ON when final setting value + over setting value
≧
compared weight value
≧
final setting value - under setting value
* 8
The timing of complete signal output depends on setting mode 2-2: complete signal output mode (shown in the chart as 1: after judging
timer elapse.)
The timing of over/under comparison holds the weight value compared at complete ON regardless of setting mode 2-2:over/under compar-
ison mode
11 After complete output timer has
elapsed
HOLD goes out
HI, GO or LO goes
out
Setting mode 1-3:
complete output time (t3)
Setting mode 2-2:
output selection (22 pin)
Over (10 pin) OFF
Under (11 pin) OFF
Output selection: GO
(22 pin) OFF
Output selection:
complete (22 pin) OFF
12 Waiting for input of start signal
for next weighing
SP1/SP2/SP3