6.FUNCTIONS
93
Near Zero confirmation at the sequence mode
Setting for confirming whether Near Zero signal ON at the start of weighing.
Weighing will normally start if the Near Zero is ON. “Sequence error 4” is displayed if the Near
Zero is OFF.
Refer to "6-12-5.Upper limit / Lower limit / Near zero" on p.78 concerning Near Zero setting.
Setting /
1 : Valid
0 : Invalid
CC-Link
0
52
MSB
LSB
RWw0006
RWw0005
RWw0004
Write the code No. and set value.
H
L
0
0 to 1
Word size
remote register
Set value
Code No.
Console
1) Select code 52.
2) Press the ENT key, and then set the near
zero confirmation.
3) Determine the setting with the ENT key.
Near zero
confirmation