VIRDI 3000
TM
User’s Manual
38
UNION COMMUNITY Co., Ltd. 44-3 Hyundai Topics Building, Bangi-dong,
Songpa-gu, Seoul, Korea 138-050, Tel: 82-2-6488-3000, Fax: 82-2-6488-3099,
E-Mail:[email protected], http://www.unioncomm.co.kr/eng
authentication mode.
Press [ENTER] to move to the next setting.
3.5.2.3. Settings for only card authentication
[Fn]
◆
Æ
[3]
Æ
[2]
Æ
[ENTER]
◆
<Only Card>
(N=0/Y=1): 0
Default setting: ‘0’
Even if a user is registered to be authenticated with a card & password or a
card & fingerprint, if it is set to [1], a user can get access to an area through
the relevant terminal only by using a card.
This function is useful at building entrance door – among other places of a
building with several installed terminals - where there is frequent entrance and
exit and there is no need for severe access control.
Press [ENTER] to move to the next setting.
3.5.2.4. 1:N authentication settings
[Fn]
◆
Æ
[3]
Æ
[2]
Æ
[ENTER]
Æ
[ENTER]
◆
<Enable 1:N>
(N=0/Y=1): 0
Default setting: ‘1’
This enables fingerprint authentication without inputting a user ID or placing a
card. For your information, even if a user is registered to be authenticated with
1:N authentication, only 1:1 authentication is allowed in the terminal if this is
set to [0].
In cases that ID input or fingerprint authentication after placing a card – when
card input replaces ID input – is unavoidably needed, it should be set to [0].
The followings are detailed settings about whether 1:N authentication is
allowed or not.
When 1:N authentication is allowed as setting of [1]
①
<User ID Group>
(N=0/Y=1): 0
Default setting: ‘0’