Unimark XP Скачать руководство пользователя страница 5

XP 

2.0 

Items Included (contents vary with customer configuration): 

1. XP 

Unit 

2. Keys 

3.  AC Power Cord 

4.  XP Manual or Product CD 

5.  Optional items such as ticket catchers, 

Bin C options, and interface cables and 
adaptors/gender changers 

6.  Sample Test Stock 

 

 

 
3.0 Product 

Specifications: 

 

Printing system: 

Method:

  

Direct Thermal 

Resolution:

   203DPI 

Speed:

  

Up to 50 documents per minute 

Font:

 

Contains Andale from Agfa Monotype Corporation

 

 

Magnetic encoding: 

Stock type:

  

ATB1 and ATB2 tickets with and without magnetic stripe 

Encoding specification:

   Conforms to IATA specification 1722C, Attachment C 

Encoding format:

  

Four tracks Read/Write verification (210 bpi) 

Pre-Encoding:

  

Standard pre-read of magnetically encoded SCN numbers 

 

Document handling: 

Types:

  

ATB1 and ATB2, 8 and 7-3/8 inch stock 

Source:

  

Two internal (Bins A and B); 7-3/8 and 8 inch stock 

 

One external (Bin C); 8 inch stock only 

Revalidation:

  

One front input feed slot; 7-3/8 and 8 inch stock 

Reject:

  

One internal reject bin 

Exit:

  

One stock path exit point at the front below the revalidation slot 

 

Interface: 

RS-232:

  

Two Asynchronous Serial Communication ports (DB-25F DTE standard) 

Ethernet:

   *

Optional network

 

interface (RJ-45) with TCP/IP and Web Server functionality

 

USB:

   

*

Optional Universal Serial Bus interface

 

Modem:

 

*

Optional Modem Phone Line (RJ-11/RJ-12) interface

 

RF:

   

*

Optional RF antenna mount

 

 

*  Not part of the Standard XP configuration 
**  Other interface options can be developed as necessary 

 

Control Panel: 

Keys:

  

Eight momentary push button keys (see “Front Panel” section for details) 

LEDs:

  

Four indicator LEDs (see “Front Panel” section for details)  

Display:

   2 row by 20 column (2x20) alpha numeric (see “Front Panel” section for details) 

 

Physical: 

Dimensions:

  

11-5/8” wide, 23-1/2” high (without casters), 21-3/4” deep 

Weight:

  

50lbs (23 kg), 

Standard Configuration

 

Shipping Container Dimensions:

   (See “Installation” section) 

 

Environmental: 

Operating Temperature:

 

40 to 104

°

F (4 to 40

°

C) 

Storage Temperature:

 

-4 to 140

°

F (-20 to 60

°

C) 

Relative Operating Humidity:

 

5 to 95%, non-condensing, without degraded performance 

Relative Storage Humidity:

 

5 to 95%, non-condensing, without damage to components 

 

Содержание XP

Страница 1: ...2004 Unimark Products LLC P N 71U 1429 100K REV C Installation and Operator s Manual Unimark Service 800 255 6356 www unimark com...

Страница 2: ...age 12 8 1 Powering the Unit On and Off 8 2 Loading Ticket Stock 9 0 Operating Under a CRS or Airline Host Page 14 10 0 Clearing Stock Jams Page 15 11 0 Cleaning Page 17 11 1 Using the Cleaning Card 1...

Страница 3: ...ote This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection agai...

Страница 4: ...ty information as well as providing visible feedback when the operator or service provider is navigating through the menu system The Unit uses an autoswitching power supply which allows automatic oper...

Страница 5: ...ternal reject bin Exit One stock path exit point at the front below the revalidation slot Interface RS 232 Two Asynchronous Serial Communication ports DB 25F DTE standard Ethernet Optional network int...

Страница 6: ...s soon as the tickets are removed To enable the Bin Full feature simply place your index finger against the top left side of the bin full bale and push slightly to the right while pulling out This act...

Страница 7: ...the Unit from overheating do not block openings on the enclosure Do not place the Unit on or near a heat source such as a radiator or heat register The Unit uses a grounded 3 prong power cable as a s...

Страница 8: ...dware interfaces including Ethernet USB and Modem Custom firmware interfaces can be written for these and the existing serial interface 5 2 Data Structure The Unit uses an asynchronous serial data tra...

Страница 9: ...ck one menu level or cancels a particular operation ALERT Notifies the operator of a condition that needs immediate attention POWER Indicates that the Unit is powered ONLINE Indicates that the Unit is...

Страница 10: ...Service Menu 3 1 Press the ONLINE key to take the Unit off line and then press the ENTER key to access the menu system 2 See Adjustments sub menu tree for further details 3 Service menu is password pr...

Страница 11: ...t Speed 7 Inches Per Second 8 Inches Per Second Burst Position Adjust Enter Value 30 to 30 Bin A xx B xx C xx Print Sample 1 Left Margin shifts the entire printed image left and right staple stub dire...

Страница 12: ...alinjury donotwearlooseclothingorjewelryanddonotstickfingers intotransportmechanismwhenloadingticketstock Thetransportmechanismcontains movingparts Readtheentireprocedurebeforeloadingticketstock 8 2 1...

Страница 13: ...tintothebininput 8 2 5 Insert ticket stock into selected bin inputs staple stub first and oriented as shown above Note that the magnetic stripe if applicable must be against the inner wall as shown Re...

Страница 14: ...on the specific customer firmware version 9 0 2 If the Unit is not on line press the ONLINE key If the Unit will not go on line refer to the Troubleshooting section for help 9 0 3 Once the Unit is on...

Страница 15: ...red press the ONLINE key to continue operation 10 0 4 If the jam condition persists complete the following procedure WARNING Topreventpersonalinjury REMOVEPOWERbeforemanuallyclearingticketstockjams 10...

Страница 16: ...move the stock through the encoder print exit and revalidation path areas 10 0 4 4 If you cannot remove the stock using the knurled knobs remove the ticket stock causing the jam through the openings...

Страница 17: ...spection cleaning procedures are presented separately for clarity but may be performed at the same time Note TheUnitcontainselectroniccircuitry solenoids andmotor drivenmechanismsthatallgenerateasmall...

Страница 18: ...e cleaning solution to evaporate 11 1 11 Press the ONLINE key and place the Unit back in the on line state 11 2 Periodic Inspection Every three months more often in high volume applications inspect th...

Страница 19: ...ck the ticket stock all the way out of the transport mechanism by turning the knurled knobs shown in the figure above 11 4 4 Remove ticket stock as necessary and vacuum dust from inside of Unit 11 4 5...

Страница 20: ...mes and remove the cloth The cloth will be discolored from the dust ink buildup on the roller 11 5 6 Dampen another area of the cloth and repeat this process until the cloth no longer discolors This w...

Страница 21: ...rint head platen Move the swab back and forth across the print head until it is clean 11 6 5 Dampen a lint free cloth with a 99 Isopropyl Alcohol cleaning solution 11 6 6 Hold the cloth firmly against...

Страница 22: ...errors can be corrected by pressing the RESET key or restarting the Unit If problems persist call the CRS or Airline host Help Desk for assistance Not Operating display shows erroneous characters Uni...

Страница 23: ...cated bin s are empty Check bin location s indicated and load stock as necessary Exit Bin Full Remove Coupons Indicates that the exit bin is full Remove stock from exit bin catcher Reject Bin Full Emp...

Страница 24: ...into the transport mechanism matching the print head assembly guide to the groove in the print head mounting block 13 0 8 Tighten the thumbscrew clockwise and secure the new print head assembly Torqu...

Страница 25: ...return process 14 1 1 Prepare item for return to Unimark Do NOT include accessories power cable or ancillary items unless directed otherwise by Customer Service DO NOT SHIP WITH TICKET STOCK INSTALLE...

Страница 26: ...l support line A technical support analyst will assist you To better serve you please have the product in question on line and ready to test prior to calling technical support In addition have the fol...

Страница 27: ...ot be responsible for any loss or damages incurred in shipping Any warranty work to be performed by Unimark shall be subject to Unimark s confirmation that such product meets Unimark warranty In the e...

Отзывы: