AC voltage detector and cyclic sense
Of the phases without contact
r18
1.
WARNINGS
Respect the safety rules indicated in the user manual.
•
Read understand and follow safety rules and operating instructions in the manual
before using this tester.
•The tester’s safety features may not protect the user if not used in accordance with
the manufacturer’s instruction
s.
•Check on a known live source within the rated AC voltage range of the tester before
use to ensure it is in working order.
•Insulation type and thickness, distance from the voltage source, shielded wires, and
other factors may effect reliable operation. Use other methods to verify live voltage,
if there is any uncertainty.
•Do not use if
the tester appears damaged or if it is not operating properly. If in doubt,
replace the tester.
•Do not use on voltages that are higher than as marked on the tester.
•Us
e caution with voltages above 30 volts AC as a shock hazard may exist.
•Comply with all
applicable safety codes. Use approved
personal protective equipment when working near live electrical circuits-particularly
with regard to arc-flash potential.
•Do not
operate tester if Low Battery warning occurs. Replace batteries immediately.
2.
International security symbols
3.
General Specifications
4.
Description Detector
1. Battery cover
2. Flashlight
3. Flashlight button
4.Phases Cyclic Sense button
5. 0n / 0ff button
6. LED indicators
7.Punta Detector
8.Worklight
5.
Operations
5-1.Turning the Tester On
Press the tester ON/OFF Button, the tester will beep once and the green LED and worklighit
will illuminate to indicate that the tester is working on high voltage mode and ready for use.
5-2.Turning the Tester Off
Press the ON/OFF Button one more time, the tester will beep twice and range LED will turn
off.
5-3.Mode Select Function
•
When the tester is on with NCV function, short press the once, the green and yellow LED
flash slowly alternately to indicate that the tester is working on phase sequence test mode.
•
Short press Button again, the yellow led off and the green LED illuminate, the tester returns
to high voltage mode.
•
The tester will beep once every Button operation
.
•
The Button operation is valid only when the NCV function is turned on
Detection Voltage Range
100V to 1000VAC
Phase Voltage Range
200V to 1000V
Frequency Range
50/60Hz
Batteries
Two AAA 1.5V batteries
Operating Temperature
0 to 50°C (32 to 122°F)
Storage Temperature
-10 to 60°C (14 to 140°F)
Humidity
80% max.
Altitude
2000 meters
Pollution Degree
2
Safety Compliance
CAT IV 1000V
IP Rating
IP67
potential danger. Indicates that the user should
refer to the Manual for important safety
information
Indicates dangerous voltages may be present
The equipment is protected by double or reinforced
insulation
dsadasdsdad
6