background image

30

  unigreen

TABLES FOR CALIBRATING ATOMISERS

TABLES FOR CALIBRATING ATOMISERS  Ø650 TGZ

TABLES FOR CALIBRATING ATOMISERS  Ø800 TGZ

N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width
indicated in the table and divide it by the new width (see chapter 6.3, page 20).

unigreen spa

Tabella erogazione in Litri/ettaro Gr.Ventola Ø650  14 getti

Lt./ha spreading rate tab le for Blower Ø650  14 NOZZLES

TR 80-01 ISO VERDE

TR 80-03 ISO BLU

Larghezza di lavoro

PRESSIONE bar

5

7

10

12

15

18

20

5

7

10

12

15

18

20

working width

3,5

727 864 1029 1131 1255 1385 1461 1467 1735 2085 2283 2551 2791 2949

4

636 756 900 990 1098 1212 1278 1284 1518 1824 1998 2232 2442 2580

5

509 605 720 792 878 970 1022 1027 1214 1459 1598 1786 1954 2064

2,5

6

424 504 600 660 732 808 852 856 1012 1216 1332 1488 1628 1720

7

363 432 514 566 627 693 730 734 867 1042 1142 1275 1395 1474

2,5 m.

3,5

606 720 857 943 1046 1154 1217 1223 1446 1737 1903 2126 2326 2457

4

530 630 750 825 915 1010 1065 1070 1265 1520 1665 1860 2035 2150

5

424 504 600 660 732 808 852 856 1012 1216 1332 1488 1628 1720

3

6

353 420 500 550 610 673 710 713 843 1013 1110 1240 1357 1433

7

303 360 429 471 523 577 609 611 723 869 951 1063 1163 1229

3 m.

3,5

454 540 643 707 784 866 913 917 1084 1303 1427 1594 1744 1843

4

398 473 563 619 686 758 799 803 949 1140 1249 1395 1526 1613

5

318 378 450 495 549 606 639 642 759 912 999 1116 1221 1290

4

6

265 315 375 413 458 505 533 535 633 760 833 930 1018 1075

7

227 270 321 354 392 433 456 459 542 651 714 797 872 921

4 m.

Litri/min.

10,6 12,6 15,0 16,5 18,3 20,2 21,3 21,4 25,3 30,4 33,3 37,2 40,7 43,0

 Tab. 3215/0000F

ug. sing.

0,76

0,9 1,07 1,18 1,31 1,44 1,52 1,53 1,81 2,17 2,38 2,66 2,91 3,07

14 GETTI

Velocità Km/h

s

p

eed

Litri/ha

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

Litri/ha

Litri/ha

unigreen spa

Tabella erogazione in Litri/ettaro Gr.Ventola Ø800  16 getti

Lt./ha spreading rate tab le for Blower Ø800  16 NOZZLES

TR 80-01 ISO VERDE

TR 80-03 ISO BLU

Larghezza di lavoro

PRESSIONE bar

5

7

10

12

15

18

20

5

7

10

12

15

18

20

working width

3,5

697 823 977 1080 1200 1314 1389 1400 1657 1983 2177 2434 2663 2806

4

610 720 855 945 1050 1150 1215 1225 1450 1735 1905 2130 2330 2455

5

488 576 684 756 840 920 972 980 1160 1388 1524 1704 1864 1964

3

6

407 480 570 630 700 767 810 817 967 1157 1270 1420 1553 1637

7

349 411 489 540 600 657 694 700 829 991 1089 1217 1331 1403

3 m.

3,5

523 617 733 810 900 986 1041 1050 1243 1487 1633 1826 1997 2104

4

458 540 641 709 788 863 911 919 1088 1301 1429 1598 1748 1841

5

366 432 513 567 630 690 729 735 870 1041 1143 1278 1398 1473

4

6

305 360 428 473 525 575 608 613 725 868 953 1065 1165 1228

7

261 309 366 405 450 493 521 525 621 744 816 913 999 1052

4 m.

3,5

418 494 586 648 720 789 833 840 994 1190 1306 1461 1598 1683

4

366 432 513 567 630 690 729 735 870 1041 1143 1278 1398 1473

5

293 346 410 454 504 552 583 588 696 833 914 1022 1118 1178

5

6

244 288 342 378 420 460 486 490 580 694 762 852 932 982

7

209 247 293 324 360 394 417 420 497 595 653 730 799 842

5 m.

Litri/min.

12,2 14,4 17,1 18,9 21,0 23,0 24,3 24,5 29,0 34,7 38,1 42,6 46,6 49,1

 Tab. 3215/0000F

ug. sing.

0,76

0,9 1,07 1,18 1,31 1,44 1,52 1,53 1,81 2,17 2,38 2,66 2,91 3,07

Velocità Km/h

s

p

eed

Litri/ha

Velocità Km/h

s

p

eed

Litri/ha

Litri/ha

16 GETTI

Velocità Km/h

s

p

eed

Содержание Mistblowers AP APC

Страница 1: ...USE AND MAINTENANCE MANUAL MISTBLOWERS MOUNTED MISTBLOWERS serie EXPO CLIO KAMBA VENUS DEVIL SIRIO EOLO AP Read this manual carefully before use GB 04 2010 ISO Color code...

Страница 2: ...OWED ATOMISERS 9 4 4 TRACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 2 HYDRAULIC CONNECTIONTOTHE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4...

Страница 3: ...8 7 2 INDICATIONS FOR A SUITABLETREATMENT OF WASTE 23 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 23 TABLES FOR CALIBRATING ATOMISERS 500 600 25 TABLES FOR CALIBRATING ATOMISERS 600 650 26 TA...

Страница 4: ...nd pipes noz zles pressure gauges oil tyres friction material of the clutches Evident cases of negligence include work speed over that indicated in the spraying tables in the handbook or too high for...

Страница 5: ...some residual risks associated with the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous...

Страница 6: ...roducts license and in any case only after having carefully read the instructions on the container 2 3 1 REGULATIONS FORTHE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accide...

Страница 7: ...machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed atomisers are not specifically designed for road use Nevertheless many models are also available in the v...

Страница 8: ...ts UNI EN 907 Nov 1998 Agricultural and forestry machinery Sprayers and spreaders of liquid fertilizers Safety UNI EN ISO 13849 1 February 2007 Machinery safety Fundamental concepts general design pri...

Страница 9: ...where the fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the...

Страница 10: ...ver bumps b Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the thi...

Страница 11: ...CTIVE COVER ON THE PUMP SHAFT 4 6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the manufacturer The pump can be identified by the ratings plate o...

Страница 12: ...ies it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically compensates variations in speed within the scope of the same ge...

Страница 13: ...e the proportional valve may not be able to compensate the speed variations correctly Adjusting the compensated returns close only one tap of section C position OFF adjust the corresponding compensato...

Страница 14: ...antipollution hydroejector mounted as standard on some models then you should proceed as follows put roughly 20 30 L of water in the tank and start the pump remove the cap of ejector E and insert fil...

Страница 15: ...be filled with clean water and used to rinse the entire circuit including the suction delivery pump pressure regulator jets and nozzles Thanks to the practical rotary nozzle it also rinses the inside...

Страница 16: ...tiplier made accessible through the opening on the side in the rear left part of the machine or at a distance on the right side The lever has 2 or 3 positions depending on the number of gears and the...

Страница 17: ...only be performed by qualified personnel respecting the position of the single vanes so as not to vary the dynamic balance of the fan unbalanced blowers can cause rapid wear of the multiplier and the...

Страница 18: ...e clutch see the previous paragraph This fan rotor can usually produce a delivery which is much higher with a very high speed airflow Fig 25 The cannon fan is mounted on a thrust block that can be adj...

Страница 19: ...etation to be treated Poor quality or worn nozzles have a tendency to create unevenly treated strips The nozzles are produced in various sizes to work with a precise pressure range to create certain t...

Страница 20: ...44 829 L ha 5 x 6 N B Depending on the season the vegetation may be more or less luxuriant bear this in mind before starting the treatment If the plants don t have much foliage you should diminish the...

Страница 21: ...int the jet at people or animals The jet can cause serious injuries simply due to the mechanical force of the liquid under pressure Never block the spraying lever of the lance in an open position beca...

Страница 22: ...level If you notice even a partial blockage of a nozzle proceed as follows drain the pressure and stop the machine dismantle the screw or bayonet ringnuts holding the nozzles clean with a small brush...

Страница 23: ...DEMOLITION AND DISPOSAL When the sprayer will be put out of service you should wash it with great care to remove any residues of chemical product follow the instructions in point 4 13 of the present...

Страница 24: ...ixing G1 4 jets on 1 2 booms 1805 0034F Clamp kit for fixing G1 4 jets on 1 2 booms M8 F thread 1805 0050F TXA80 005 Lilac 3400 0611F ISO nozzle TXA80 067 Olive 3400 0612F ceramic conical TXA80 01 Ora...

Страница 25: ...07 346 425 487 542 597 686 754 5 m Litri min 15 0 17 2 19 6 21 8 23 7 27 0 29 6 20 2 24 8 28 4 31 6 34 8 40 0 44 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3 55 3 95 4 35 5...

Страница 26: ...20 466 507 578 634 434 531 609 677 746 857 943 5 m Litri min 18 8 21 5 24 5 27 2 29 6 33 7 37 0 25 3 31 0 35 5 39 5 43 5 50 0 55 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3...

Страница 27: ...7 387 442 504 559 609 693 761 521 638 730 813 895 1029 1131 5 m Litri min 22 6 25 8 29 4 32 6 35 5 40 4 44 4 30 4 37 2 42 6 47 4 52 2 60 0 66 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Страница 28: ...490 544 591 674 740 506 620 710 790 870 1000 1100 6 m Litri min 26 3 30 1 34 3 38 1 41 4 47 2 51 8 35 4 43 4 49 7 55 3 60 9 70 0 77 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 1...

Страница 29: ...7 430 491 560 621 677 770 846 579 709 811 903 994 1143 1257 6 m Litri min 30 1 34 4 39 2 43 5 47 4 53 9 59 2 40 5 49 6 56 8 63 2 69 6 80 0 88 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Страница 30: ...4 m Litri min 10 6 12 6 15 0 16 5 18 3 20 2 21 3 21 4 25 3 30 4 33 3 37 2 40 7 43 0 Tab 3215 0000F ug sing 0 76 0 9 1 07 1 18 1 31 1 44 1 52 1 53 1 81 2 17 2 38 2 66 2 91 3 07 14 GETTI Velocit Km h s...

Страница 31: ...5 205 253 291 323 356 413 468 343 419 485 544 592 683 768 18 6 171 211 242 269 297 344 390 286 349 404 453 493 569 640 7 147 181 208 231 254 295 334 245 299 347 389 423 488 549 18 m Litri min 31 38 4...

Страница 32: ...17 579 631 730 910 5 269 328 380 426 463 534 601 292 359 413 463 505 584 728 23 6 224 273 317 355 386 445 501 243 299 344 386 421 487 607 7 192 234 271 304 331 382 429 209 256 295 331 361 417 520 23 m...

Страница 33: ...7 387 434 473 548 683 5 201 246 285 319 347 401 451 219 269 310 347 379 438 546 23 6 168 205 237 266 290 334 376 183 224 258 290 316 365 455 7 144 176 203 228 248 286 322 157 192 221 248 271 313 390 2...

Страница 34: ...1 0 70 1 01 1 52 2 07 3 07 4 08 5 09 Code 3400 0611F 3400 0612F 3400 0613F 3400 0614F 3400 0615F 3400 0616F 3400 0617F TAB 3 ISO TABLE OF DELIVERY IN LITRES MIN MEDIUM AND HIGHVOLUME 18 CONICAL NOZZLE...

Страница 35: ...one 3 40 4 40 6 20 6 80 8 10 9 20 11 2 direct jet 4 10 5 40 8 30 11 8 15 1 19 1 24 6 TABLE 4 TABLE 4 5 TABLES OF DELIVERY OF NOZZLES FOR HAND LANCES TABLE OF DELIVERY IN LITRES MIN OFTHE CONICAL NOZZL...

Страница 36: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Страница 37: ...X X X X X X X X X X REGULATOR RVA 2 4 5 WAY X X X X X X X X X X X X X X X X X X RM 40 S X X X X X X X X X X X X X GCPElectric X X X X X X X JETS SINGLENON DRIP X X X X X X X X X X X X X X X X X X DOUB...

Страница 38: ...X X X X X X X X REVERBERI AR 1064 1053 X PRESSURE GCP RVA X X X X X X X X X X X X X REGULATOR ORION Comet X X X X X X X X X X X X X GCP ELECTRIC X X X X X X X X X X X X X JETS SINGLENON DRIP X X X X X...

Страница 39: ...5 1203 X X X X BHA 160 X X X PRESSURE RVA X X X X X X X X REGULATOR ORION Comet X X X X X X GCPELECTRIC X X X X X X JETS P39 X X SINGLENON DRIP X X X X X X X X DOUBLENON DRIP X X X X X X X X TYREMFC X...

Страница 40: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Отзывы: