TABLES FOR CALIBRATING CANNONS

TABLES FOR CALIBRATING CANNONS Ø400-455 TILTING HEAD

N.B. to calculate the different ranges extension it is sufficient to multiply the value lt/hectare by the corresponding
width indicated in the table and divide it by the new width (see chapter 6.3, page 20).

N.B. to obtain better agitaton in the tank, verify that the total lt/min. spray delivery does not exceed 75% of the
pump delivery. For example, with an APS 121  select a maxium setting of 86 lt/min.

N.B. to obtain better agitaton in the tank, verify that the total lt/min. spray delivery does not exceed 75% of the
pump delivery. For example, with an APS 121  select a maxium setting of 86 lt/min.

Tabella erogazione in Litri/ettaro Cannone Ø400  6 getti Testa Snodata

unigreen spa

Lt./ha spreading rate tab le for Cannone Blower Ø4005  6 NOZZLES Tilting Head

Piastrina ceramica Ø1,8

Piastrina ceramica Ø2

Gittata

PRESSIONE bar

10

15

20

25

30

40

50

10

15

20

25

30

40

50

spray distance

3,5

441

538

624

699

761

878

987

480

590

679

761

830

960 1197

4

386

471

546

612

666

768

864

420

516

594

666

726

840 1047

5

309

377

437

490

533

614

691

336

413

475

533

581

672

838

15

6

257

314

364

408

444

512

576

280

344

396

444

484

560

698

7

221

269

312

350

381

439

494

240

295

339

381

415

480

598

15 m.

3,5

368

449

520

583

634

731

823

400

491

566

634

691

800

997

4

322

393

455

510

555

640

720

350

430

495

555

605

700

873

5

257

314

364

408

444

512

576

280

344

396

444

484

560

698

18

6

214

262

303

340

370

427

480

233

287

330

370

403

467

582

7

184

224

260

291

317

366

411

200

246

283

317

346

400

499

18 m.

3,5

288

351

407

456

496

572

644

313

385

443

496

541

626

780

4

252

307

356

399

434

501

563

274

337

387

434

473

548

683

5

201

246

285

319

347

401

451

219

269

310

347

379

438

546

23

6

168

205

237

266

290

334

376

183

224

258

290

316

365

455

7

144

176

203

228

248

286

322

157

192

221

248

271

313

390

23 m.

Litri/min.

39

47

55

61

67

77

86

42

52

59

67

73

84

105

 Tab. 3215/0000F

ug. sing.

6,44

7,85

9,10 10,20 11,10 12,80 14,40 7,00

8,60

9,90 11,10 12,10 14,00 17,45

Litri/ha

Litri/ha

Litri/ha

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

Tabella erogazione in Litri/ettaro Cannone Ø455  6 getti Testa Snodata

unigreen spa

Lt./ha spreading rate tab le for Cannone Blower Ø455  6 NOZZLES Tilting Head

Piastrina ceramica Ø1,8

Piastrina ceramica Ø2

Gittata

PRESSIONE bar

10

15

20

25

30

40

50

10

15

20

25

30

40

50

spray distance

3,5

331

404

468

525

571

658

741

360

442

509

571

622

720

897

4

290

353

410

459

500

576

648

315

387

446

500

545

630

785

5

232

283

328

367

400

461

518

252

310

356

400

436

504

628

20

6

193

236

273

306

333

384

432

210

258

297

333

363

420

524

7

165

202

234

262

285

329

370

180

221

255

285

311

360

449

20 m.

3,5

221

269

312

350

381

439

494

240

295

339

381

415

480

598

4

193

236

273

306

333

384

432

210

258

297

333

363

420

524

5

154

188

218

245

266

307

346

168

206

238

266

290

336

419

30

6

129

157

182

204

222

256

288

140

172

198

222

242

280

349

7

110

135

156

175

190

219

247

120

147

170

190

207

240

299

30 m.

3,5

184

224

260

291

317

366

411

200

246

283

317

346

400

499

4

161

196

228

255

278

320

360

175

215

248

278

303

350

436

5

129

157

182

204

222

256

288

140

172

198

222

242

280

349

36

6

107

131

152

170

185

213

240

117

143

165

185

202

233

291

7

92

112

130

146

159

183

206

100

123

141

159

173

200

249

36 m.

Litri/min.

39

47

55

61

67

77

86

42

52

59

67

73

84

105

 Tab. 3215/0000F

ug. sing.

6,44

7,85

9,10 10,20 11,10 12,80 14,40 7,00

8,60

9,90 11,10 12,10 14,00 17,45

Litri/ha

Litri/ha

Litri/ha

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

Содержание Mistblowers AP APC

Страница 1: ...USE AND MAINTENANCE MANUAL MISTBLOWERS MOUNTED MISTBLOWERS serie EXPO CLIO KAMBA VENUS DEVIL SIRIO EOLO AP Read this manual carefully before use GB 04 2010 ISO Color code...

Страница 2: ...OWED ATOMISERS 9 4 4 TRACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 2 HYDRAULIC CONNECTIONTOTHE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4...

Страница 3: ...8 7 2 INDICATIONS FOR A SUITABLETREATMENT OF WASTE 23 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 23 TABLES FOR CALIBRATING ATOMISERS 500 600 25 TABLES FOR CALIBRATING ATOMISERS 600 650 26 TA...

Страница 4: ...nd pipes noz zles pressure gauges oil tyres friction material of the clutches Evident cases of negligence include work speed over that indicated in the spraying tables in the handbook or too high for...

Страница 5: ...some residual risks associated with the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous...

Страница 6: ...roducts license and in any case only after having carefully read the instructions on the container 2 3 1 REGULATIONS FORTHE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accide...

Страница 7: ...machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed atomisers are not specifically designed for road use Nevertheless many models are also available in the v...

Страница 8: ...ts UNI EN 907 Nov 1998 Agricultural and forestry machinery Sprayers and spreaders of liquid fertilizers Safety UNI EN ISO 13849 1 February 2007 Machinery safety Fundamental concepts general design pri...

Страница 9: ...where the fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the...

Страница 10: ...ver bumps b Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the thi...

Страница 11: ...CTIVE COVER ON THE PUMP SHAFT 4 6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the manufacturer The pump can be identified by the ratings plate o...

Страница 12: ...ies it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically compensates variations in speed within the scope of the same ge...

Страница 13: ...e the proportional valve may not be able to compensate the speed variations correctly Adjusting the compensated returns close only one tap of section C position OFF adjust the corresponding compensato...

Страница 14: ...antipollution hydroejector mounted as standard on some models then you should proceed as follows put roughly 20 30 L of water in the tank and start the pump remove the cap of ejector E and insert fil...

Страница 15: ...be filled with clean water and used to rinse the entire circuit including the suction delivery pump pressure regulator jets and nozzles Thanks to the practical rotary nozzle it also rinses the inside...

Страница 16: ...tiplier made accessible through the opening on the side in the rear left part of the machine or at a distance on the right side The lever has 2 or 3 positions depending on the number of gears and the...

Страница 17: ...only be performed by qualified personnel respecting the position of the single vanes so as not to vary the dynamic balance of the fan unbalanced blowers can cause rapid wear of the multiplier and the...

Страница 18: ...e clutch see the previous paragraph This fan rotor can usually produce a delivery which is much higher with a very high speed airflow Fig 25 The cannon fan is mounted on a thrust block that can be adj...

Страница 19: ...etation to be treated Poor quality or worn nozzles have a tendency to create unevenly treated strips The nozzles are produced in various sizes to work with a precise pressure range to create certain t...

Страница 20: ...44 829 L ha 5 x 6 N B Depending on the season the vegetation may be more or less luxuriant bear this in mind before starting the treatment If the plants don t have much foliage you should diminish the...

Страница 21: ...int the jet at people or animals The jet can cause serious injuries simply due to the mechanical force of the liquid under pressure Never block the spraying lever of the lance in an open position beca...

Страница 22: ...level If you notice even a partial blockage of a nozzle proceed as follows drain the pressure and stop the machine dismantle the screw or bayonet ringnuts holding the nozzles clean with a small brush...

Страница 23: ...DEMOLITION AND DISPOSAL When the sprayer will be put out of service you should wash it with great care to remove any residues of chemical product follow the instructions in point 4 13 of the present...

Страница 24: ...ixing G1 4 jets on 1 2 booms 1805 0034F Clamp kit for fixing G1 4 jets on 1 2 booms M8 F thread 1805 0050F TXA80 005 Lilac 3400 0611F ISO nozzle TXA80 067 Olive 3400 0612F ceramic conical TXA80 01 Ora...

Страница 25: ...07 346 425 487 542 597 686 754 5 m Litri min 15 0 17 2 19 6 21 8 23 7 27 0 29 6 20 2 24 8 28 4 31 6 34 8 40 0 44 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3 55 3 95 4 35 5...

Страница 26: ...20 466 507 578 634 434 531 609 677 746 857 943 5 m Litri min 18 8 21 5 24 5 27 2 29 6 33 7 37 0 25 3 31 0 35 5 39 5 43 5 50 0 55 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3...

Страница 27: ...7 387 442 504 559 609 693 761 521 638 730 813 895 1029 1131 5 m Litri min 22 6 25 8 29 4 32 6 35 5 40 4 44 4 30 4 37 2 42 6 47 4 52 2 60 0 66 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Страница 28: ...490 544 591 674 740 506 620 710 790 870 1000 1100 6 m Litri min 26 3 30 1 34 3 38 1 41 4 47 2 51 8 35 4 43 4 49 7 55 3 60 9 70 0 77 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 1...

Страница 29: ...7 430 491 560 621 677 770 846 579 709 811 903 994 1143 1257 6 m Litri min 30 1 34 4 39 2 43 5 47 4 53 9 59 2 40 5 49 6 56 8 63 2 69 6 80 0 88 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Страница 30: ...4 m Litri min 10 6 12 6 15 0 16 5 18 3 20 2 21 3 21 4 25 3 30 4 33 3 37 2 40 7 43 0 Tab 3215 0000F ug sing 0 76 0 9 1 07 1 18 1 31 1 44 1 52 1 53 1 81 2 17 2 38 2 66 2 91 3 07 14 GETTI Velocit Km h s...

Страница 31: ...5 205 253 291 323 356 413 468 343 419 485 544 592 683 768 18 6 171 211 242 269 297 344 390 286 349 404 453 493 569 640 7 147 181 208 231 254 295 334 245 299 347 389 423 488 549 18 m Litri min 31 38 4...

Страница 32: ...17 579 631 730 910 5 269 328 380 426 463 534 601 292 359 413 463 505 584 728 23 6 224 273 317 355 386 445 501 243 299 344 386 421 487 607 7 192 234 271 304 331 382 429 209 256 295 331 361 417 520 23 m...

Страница 33: ...7 387 434 473 548 683 5 201 246 285 319 347 401 451 219 269 310 347 379 438 546 23 6 168 205 237 266 290 334 376 183 224 258 290 316 365 455 7 144 176 203 228 248 286 322 157 192 221 248 271 313 390 2...

Страница 34: ...1 0 70 1 01 1 52 2 07 3 07 4 08 5 09 Code 3400 0611F 3400 0612F 3400 0613F 3400 0614F 3400 0615F 3400 0616F 3400 0617F TAB 3 ISO TABLE OF DELIVERY IN LITRES MIN MEDIUM AND HIGHVOLUME 18 CONICAL NOZZLE...

Страница 35: ...one 3 40 4 40 6 20 6 80 8 10 9 20 11 2 direct jet 4 10 5 40 8 30 11 8 15 1 19 1 24 6 TABLE 4 TABLE 4 5 TABLES OF DELIVERY OF NOZZLES FOR HAND LANCES TABLE OF DELIVERY IN LITRES MIN OFTHE CONICAL NOZZL...

Страница 36: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Страница 37: ...X X X X X X X X X X REGULATOR RVA 2 4 5 WAY X X X X X X X X X X X X X X X X X X RM 40 S X X X X X X X X X X X X X GCPElectric X X X X X X X JETS SINGLENON DRIP X X X X X X X X X X X X X X X X X X DOUB...

Страница 38: ...X X X X X X X X REVERBERI AR 1064 1053 X PRESSURE GCP RVA X X X X X X X X X X X X X REGULATOR ORION Comet X X X X X X X X X X X X X GCP ELECTRIC X X X X X X X X X X X X X JETS SINGLENON DRIP X X X X X...

Страница 39: ...5 1203 X X X X BHA 160 X X X PRESSURE RVA X X X X X X X X REGULATOR ORION Comet X X X X X X GCPELECTRIC X X X X X X JETS P39 X X SINGLENON DRIP X X X X X X X X DOUBLENON DRIP X X X X X X X X TYREMFC X...

Страница 40: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Отзывы: