CIB UNIGAS - M039177CA
27
2
startup the burner by turning its main switch A to on: if the burner locks (LED B on in the control panel) press the RESET button (C)
on the control panel.
The burner is factory-set with the head in its MAX position (maximum outuput).
To let the burner operate at a lower output, loose the VB screw and move progressively back the combustion head towards the MIN
position, by turning clockwise the VRT ring nut. Fasten VB screw when the adjustment is accomplished.
Now, adjust the burner according to the servocontrol model provided.
A
C
B
VRT
VB
“MAX” head position
head position