I n s t a l l a t i o n & P r o g r a m m i n g M a n u a l
54
Reset all extensions to ring for all exchange lines
Extensions to ring for MSN numbers
Add an extra extension to ring on MSN number
Stop an extension ringing on MSN number
Extensions to ring in extension groups
Add an extension to ringing in extension group
Remove an extension from ringing in extension group
Ringing cadences
Swap internal and external ring cadence
Use normal internal and external ring cadence
Use Normal Ring Cadence for calls on line 1 (206 only)
SYSTEM SETTINGS
Miscellaneous
Exch 1 normal cadence
Use Different Ring Cadence for calls on line 1 (206 only)
SYSTEM SETTINGS
Miscellaneous
Exch 1 special cadence
Use Normal Ring Cadence for calls on line 1 (208/212 only)
SYSTEM SETTINGS
Miscellaneous
Exch 1 normal cadence
Use Different Ring Cadence for calls on line 1 (208/212 only)
SYSTEM SETTINGS
Miscellaneous
Exch 1 special cadence
Security Alarm Programming
Description
The system has two independent alarm sensor ports. These can support single contacts, multiple
contacts, passive infra-red devices, outputs from current alarm systems or smoke detectors, in series
for normally closed or in parallel for normally open contacts. The system can ring extensions
internally and dial out to up to two different external numbers when the alarm is activated, with a
voice message if the fax/voice message option card is fitted.
Alarm Sensors
The system provides two alarm ports to which alarm sensors may be attached, see Figure 4-3on page
65 (206) or Figure 4-4 on page 66 (208). These may be programmed and set independently as
normally open or normally closed contacts. If the alarm contact changes from its normal state then
the alarm is triggered. An optional entry delay of 90 seconds may be added to give the user time to
disarm the alarm when entering the alarmed area. An alarm loop may also be programmed as a social
alarm. In this case, the alarm is triggered if the loop does not change state for a period of 24 hours.
Alarm sensor 2 can also operate as a switch to select between day and night operation modes, for
information see the section 'Manual Day/Night Setting with switch' on page 44.
Alarm Notification
Whenever an alarm is triggered then the system can ring internal extensions, ring external telephone
numbers, or both.
Internal notification will ring all extensions for a period of 30 seconds. This ring may be
stopped temporarily by going off-hook at any extension. This internal alarm repeats every 5
minutes until the alarm is correctly reset.
External notification will make an external call and can use a voice message or a special alarm
tone to warn the user of the alarm. Up to 2 external numbers may be dialled a maximum of 255
times until the alarm is correctly acknowledged. The flow diagram used for external alarm calls
is shown in Figure 3-8 on page 55.
External alarm without notification is silenced by answering the external call.
MSN_entry, ext
MSN_entry, ext
group, ext1, ext2,… ext n
group, ext1, ext2,… ext n
PIN
PIN
PIN
PIN