Unit Operation
When the door is open, the air curtain design directs cold ais
across the cabinet opening, keeping the ambient air out and cold
air in the cabinet for approximately 45 minutes. The unit will
maintain 45°F box temperature at 70°F ambient with the door
open, quickly returning to normal refrigerated temperatures of
36°F with the door closed. This unit is capable of maintaining 40°F
or below at 100°F ambient with the door closed.
When loading product in the cabinet allow enough space for
proper air flow circulation. When operating with the door open,
keep install trays on all the shelf brackets and pushed in all the
way to prevent disruption of the air flow.
Open the door completely and latch to the side of the cabinet
body while loading and unloading.
The power switch should be turned off and the power cord
disconnected whenever performing maintenance functions or
cleaning the interior of the refrigerated cabinet.