adjuSting tHe Manual gain COntrOl
The Uniden U60 4G (UNI-2005-CPAL) allow you to manually attenuate the db gain
of the device in increments of 5 and 10 db with a maximum of 15 db.
The manual gain control (MGC) adjusts the overall amplification level (gain) of the
booster. The Manual Gain Control is used to resolve the issue of oscillation without
the need of readjusting your antennas, in most cases.
The MGC allows you to easily reduce the amount of gain (amplification) the
booster is emitting. This is done with a set of dip switches to attenuate the gain on
the side of the booster.
There are four sets of dip switches, when put into the “ON” position will reduce the
gain of the booster for the designated frequency. When the LED alarms indicate
oscillation (turns orange, red or off) you need to reduce the gain of booster for the
appropriate frequency. Do this gradually in order to determine the ideal level.
The Uniden U60 4G (uni-2005-cpal) can be have the gain reduced by 5, 10, or
15 db. When a dip switch is moved up to the “ON” position it will implement
a reduction for the amount of gain indicated. Therefore, to implement a 5 db
reduction, push the dip switch marked 5 up. To implement a 10 db reduction
push the dip switch marked 10 up. To implement a 15 db reduction push both dip
switches marked 5 and 10 up.