18 June 7 , 2004
H
Select this key to display the
Features screen. For more information about this
screen, see “Features Options” on page 35.
I
Select this key to reset all fields to their default values.
NOTE:
This will overwrite any changes you have made without having saved to
a configuration file.
j
Selecting this key returns the program to the Main menu.
NOTE:
You can also press
F
.
Field Name
Field Description
Value(s)
Serial No.
Display only. This 10-character field is an identifying number
programmed into the pager at the factory. The number
displayed should match the one displayed on one of the
labels on the pager. If the label is not available, refer to the
order form for the appropriate serial number.
(display only)
Inventory Control No.
This field allows you to type a number with up to ten-
characters that is stored in the pager. Unlike the serial
number, this number can be changed as needed.
(user-defined value)
Operating Mode
This field determines whether the pager has the capability (at
the user’s discretion) to emit both audible and vibrate alerts
(
Standard
) or only vibrate alerts (
Deaf
).
NOTE:
This setting also applies to priority alerts.
Standard
Deaf
Frequency
This field designates the frequency of the receiver within the
pager.
(determined by valid
ranges supported for either
crystallized or synthesized
receivers)
ADDR 1
ADDR 2
ADDR 3
•
•
ADDR 16
Display only. Each address is the result of a calculation
performed to determine the pager’s capcodes. (Additionally,
the
Decimal Address
,
Frame
, and
Battery Cycle
values are used for the calculation.) Each even address can
contain up to 7-digits. Each odd address can contain up to
9-digits. Up to 2 frames are recommended. A frame is the
remaining number of the division of a pager capcode by 8.
N/A
FLEX Address
Display only. This address value is calculated and displayed
when you insert a decimal address.
N/A
Function
Key
Description
PAGER PROGRAMMING SOFTWARE Product Family Alpha Elite
Using Your PPS