Casing mounting sequence for TX N 840
(Ref. figs. 24 and 25)
A) Fit the insulation blanket (1) onto the boiler
shell and secure it in to place using the
elasticated straps (2) provided, ensuring
that the metal clips grip in to the external
surface of the insulation.
B) Locate the side panels (pos. 3, 4, 5 and
6) hooking them to the upper and lower
profiles.
To determine which one is the left or right
hand side front panel ensure that the cable
glands are positioned facing toward the
front edge.
C) Fit the four screws pos. 7 on the inner
upper rear side panels.
D) Open the combustion chamber door and
fit the front insulation (pos. 8), inserting
the hinges in the insulation pre-cuts.
Note: because the front insulation is suitable
for two different boiler ranges, before
removing the precut insulation, follow the
instructions supplied with the insulation it
self.
E) After removal of the two side screws from
the panel board rotate its cover frontwards
and insert the cables and the capillaries of
thermometer and thermostats through the
slots on its base.
Fit the panel board to front upper panel (9).
Fit the upper panel (9), complete with the
panel board to the side upper panels (3 & 5).
Guide the burner plug through the side
cable clamp plate (16) on the preferred
side and clamp the cable using the cable
clamp supplied.
Fix the side cable clamp plates (16) to the
casing side panels (3 & 5).
Fit the cables, leaving the boiler from the
back side, with the plastic screws of the
cable clamps (15).
F) Insert the thermometer and thermostat
bulbs in the bulb holders as shown in fig.
25 and connect the mains, the burner, the
pump(s) and any ancillary equipment to
the panel board.
Close the panel board.
Guide the burner plug through the side
cable clamp plate (16) on the preferred
side and clamp the cable using the cable
clamp supplied.
G) Fit the longitudinal upper panels (pos. 10
and 11) to the side panels.
H) Fit the rear insulation (pos. 12) and fix the
rear lower panel (pos. 13).
I) Fit the rear upper panel (pos. 14).
L) Fit the plastic cable clamps (pos. 15) onto
the rear upper panel (pos. 14).
Fit the cables, leaving the boiler from the
back side, with the plastic screws of the
cable clamps (15).
M) Remove the protective paper film from
data plate and ventilation requirement label
and fit them at the top front corner of the most
accessible side panel after
removal of dust from the surface.
The data plate and label are in the
documents envelope.