22
9
10
2
5
6
3a
3b
11
12
13
4a 5
1
4b
7
8
14
TRIOPREX N 1100÷1900
Guide the burner plug through the side
cable clamp plate (5) on the preferred side
and clamp the cable using the cable clamp
supplied.
Fix the side cable clamp plates (5) to the
casing side panels (3a & 4a).
Fit the cables, leaving the boiler from the
back side, with the plastic screws of the
cable clamps (10).
H) Fit the longitudinal upper panels (pos. 12
and 13) to the side panels.
I) Remove the protective paper film from
data plate and ventilation requirement label
(12) and fit them at the top front corner of the
most accessible side panel after removal of
dust from the surface.
The data plate and label are in the
documents envelope.
Casing mounting sequence for TX-N 1100/
1900 (Ref. figs. 26 & 27)
A) Fit the insulation blanket (1) onto the boiler
shell and secure it in to place using the
elasticated straps (2) provided, ensuring
that the metal clips grip in to the external
surface of the insulation.
Make a covenient cut in the upper part of
the insulation blanket to get easy access
to the bulb holders.
B) Position the side panels (3a, 3b and 4a,
4b) with the lower bend inside the bottom
L profiles and hook them to the screws
fitted to the upper profiles.
To determine which one of the front side
panels is the left or the right ensure that
the cable clamp plates (5) are positioned
facing toward the front edge.
C) Open the combustion chamber door and
fit the front insulation (pos. 6), inserting
the hinges in the insulation pre-cuts.
Insert the side ends of the insulation under
the bend of the two side panels (3a & 4a).
D) Fit the rear insulation (pos. 7) and fix the
rear lower panel (pos. 8) .
E) Fit the rear upper panel (pos. 9) and fit
onto it the plastic cable clamp (pos. 10).
F) After removal of the two side screws from
the panel board rotate its cover frontwards
and insert the cables and the capillaries of
thermometer and thermostats through the
slots on its base.
Fit the panel board to front upper front
panel (11).
Fit the upper front panel (11), complete with
the panel board to the side panels (3a &
4a).
G) Insert the thermometer and thermostat
bulbs in the bulb holders as shown in fig.
26 and connect the mains, the burner, the
pump(s) and any ancillary equipment to
the panel board.
Close the panel board.
fig. 27