background image

12

Instruction for the installer

As a safety measure against gas leaks,
Unical recommends installing a surveillance
and protective system composed of a gas
leakage detector combined with an on-off
selenoid valve fitted on the gas supply line.

The gas supply pipe must have a section which is identical
or greater then the one used on the boiler and must assure
a correct gas pressure.
It is however important to comply with the National or Local
Installation Standards.
Before commissioning an internal gas distribution system
and therefore before connecting it to the gas meter, the
complete installation must be tested for gas soundness.
If any part of the system is concealed from view the gas
soundness test must be carried out before covering the
pipes.
Before connecting the pipework the system must be tested
with air or inert gas at a pressure of at least 100mbar.
Before commissioning the boiler ensure that the following
operations are carried out:
- Open the gas meter cock and vent the air contained in the
piping and subsequently proceed to vent device by device.
- Check, with the gas cock turned off, that there are no gas
leaks. During the 2

nd 

quarter of the hour from the start of the

test, no pressure reduction should be detected by the
pressure gauge. Any gas leaks must be found by using only
water soap solutions, or an equivalent product, and
eliminated. 

Never look for gas leaks using a naked flame

.

3.6 - GAS CONNECTION

DANGER!
The gas connection must be carried out
only by a qualified engineer who will have
to respect and comply to the regulations in
force and to the requirements indicated by
the local gas supplier. An incorrect
installation could cause injury to persons,
animals or damage to property. The
manufacturer shall not be held liable for
any injury and/or damage.

Before installing the boiler it is
recommended to thoroughly clean all the
fuel feed pipework in order to remove any
eventual residual grime which could
compromise the boilers correct
functioning.

If you smell gas:
a. Do not turn on or off electrical switches,
use the telephone or any other object
which can provoke sparks;
b. Open all doors and windows in order to
allow fresh air to enter and purify the room;
c. Close all gas cocks;
d. Contact a service engineer, qualified
installer or the gas supply company.

The water supply pressure has to be within 1
and 4 bar.  In case of pressure higher  than 5 bar
we suggest to fit a pressure reducing valve.

WARNING!
The hardness of the feeding water conditions
the descaling frequency of heat exchanger.
Depending on the hardness of the feeding wa-
ter it must be taken into consideration the ins-
tallation possibility of dosing devices of pro-
ducts for human use for the treatment of the
domestic water.
When the water hardness is higher than 15°f
the water treatment is always suggested.

Ascertain that the water pipes are not used as
earthing of the electrical or thelephon installa-
tions. They are not absolutely suitable for this
use. In a short time this could cause serious
damage to the piping and to the water heater.

3.7 - WATER CONNECTIONS

WARNING!
Before connecting the water heater to the
water supply and distribution system we
recommend that the system is flushed out
with a product suitable for human use  in
order to eliminate any metallic tooling or
brazing residues, oil and grime which could
reach the exchanger and affect the proper
running of the water heater.
Non-observance of these instructions
could cause injury to persons, animals or
damage to property. The manufacturer
shall not be held liable for any such injury
and/or damage.

The hot water distribution pipe and the cold water supply pipe
have to be connected to the relevant 1/2” connections  

C

 and

F

 as shown on page 

11.

It is suggested to fit a gate valve at the inlet of cold water.

Содержание IDRONIK TN 14

Страница 1: ...00333640 2nd edition 04 2011 INSTRUCTIONS FOR INSTALLER USER AND SERVICE MAN IDRONIK TN 14 Instantaneousgas water heater type B ...

Страница 2: ...e user 3 1 5 Safety warnings 4 1 6 Data badge 5 1 7 Guarantee condizions 5 1 8 General warnings 6 2 TECHNICAL FEATURES AND DIMENSIONS 7 2 1 Technical features 7 2 2 Dimensions 7 2 3 Main components 8 2 4 Operational data 8 2 5 General features 8 3 INSTRUCTIONS FOR THE INSTALLER 9 3 1 General warnings 9 3 2 Installation standards 10 3 3 Packaging 10 3 4 Water heater location 11 3 5 Water heater ins...

Страница 3: ...e it is recommended to adjust the domestic hot water temperature as near as possible to the one you really require We recommend you to check the state of cleanliness of the heat exchanger at the end of the first year and subsequently on the basis of the lime scale found this period can be extended to two years 1 4 INFORMATIONS TO BE HANDED OVER TO THE USER 1 GENERAL INFORMATION The user has to be ...

Страница 4: ...r loosening the screw pipe connections use only adequate fork spanners The improper use and or the use of inadequate equipment can cause damages for example water or gas leakages WARNING Indications for appliances operating with propane gas Ensure yourself that before installing the appliance the gas tank has been purged For a correct purging of the tank contact the liquid gas supplier or a compet...

Страница 5: ...ass A Features of the D H W circuit 7 Pn Nominal Output 8 Qmax Nominal max input 9 PW Max D H W Working Pressure 10 T max Max D H W Working Temperature B Electrical Data 11 Electrical supply 12 Electrical consumption 13 Protection degree C Factory settings 14 Adjusted for gas type X D Destination countries 15 Direct and indirect destina tion countries 16 Gas category 17 Feeding pressure 18 Space f...

Страница 6: ...of the ON OFF switch and or by means of the appropriate shutdown devices In the event of failure and or faulty functioning of the appliance switch off the appliance Do not attempt to make any repairs contact qualified technicians Any repairs must be carried out by Unical authorized technicians and using only original spare parts Non observance of the above requirement may jeopardize the safety of ...

Страница 7: ...y II2H3P The gas water heater IDRONIK TN is complete with all the safety and control devices foreseen by the relevant Standar ds Furthermore it complies with Gas Appliances Directive 2009 142 EC ElectroMagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC 2 TEHNICAL FEATURES AND DIMENSIONS 2 2 DIMENSIONS COMPONENTS DESCRIPTION Atmospheric burner Ultraflat wet chamber heat e...

Страница 8: ...put Nominal output Pn Minimum output Efficiency at nominal load Efficiency at partl load Gas type Category Nominal gas feeding pressure Burner nozzle N Off Burner nozzle Ø Smoke evacuation type kW kW kW kW mbar mm IDRONIK TN 14 2 3 MAIN COMPONENTS 1 D H W outlet1 2 2 Gas valve 3 Burner 4 Heat exchanger 5 Combustion chamber 6 Flue outlet Ø 120 7 Ignition ionisation electrode 8 Flow switch 9 Batteri...

Страница 9: ... other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The connection between the boiler and chimney flue outlet can be made only after this verification has been carried out WARNING In rooms where aggressive vapours or dust are present the appliance must operate independently from ...

Страница 10: ...anty card Nr 2 spare parts request coupons DO NOT DISPERS IN THE ENVIRONMENT A 450 B 825 C 210 3 2 STANDARD CODES FOR INSTALLA TION IDRONIK TN is of the gas category II2H3P The appliance must be installed in compliance to the instructions contained in this manual The installation must be carried out by a competent qualified engineer whom will assume the esponsibility of complying to all the local ...

Страница 11: ...g with the gas type available This is verifiable via the indication on the packaging and on the data badge c Check that the chimney flue pipe has an adequate draught does not have any constrictions and that no other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The connection betw...

Страница 12: ...fore installing the boiler it is recommended to thoroughly clean all the fuel feed pipework in order to remove any eventual residual grime which could compromise the boilers correct functioning If you smell gas a Do not turn on or off electrical switches use the telephone or any other object which can provoke sparks b Open all doors and windows in order to allow fresh air to enter and purify the r...

Страница 13: ...room is not a bed room The adjacent room is not a common part of the building and is not a room with fire danger e g a fuel deposit a garage etc 3 9 FLUE GAS DISCHARGE SYSTEM Connection to the chimney A good chimney is very important for the correct functioning of the boiler it must therefore conform with the following requirements it must be made from waterproof material and be resistant at the t...

Страница 14: ...for the installer 2 Ø min Slope min 3 Ø 1 5 m min 2 Ø 1 m max 1 5 m min 2 Ø Ø Slope min 3 1 m max 2 Ø min 3 Ø 3 Ø DIMENSIONS FOR THE CONNECTION OF THE SMOKE EVACUATION DUCT MINIMUM CLEARANCES 150 150 200 Ø 120 71 200 ...

Страница 15: ...uch the appliance with any wet part of your body and or barefooted Do not pull the supply cables Do not expose the boiler to sunlight rain etc unless it is explicitly foreseen Do not permit children or inexpert people to use the appliance Ignition battery housing The appliance doesn t need to be connected to the electrical supply 230V It is fed by two 1 5 V batteries type D LR20 E95 AM1 ...

Страница 16: ...ormations to be passed on to the user The user must be instructed on the use and operation of his water heater and in particular Hand over to the end user this manual as well as all the other literature relative to the appliance and placed in the envelope contained in the packaging The user must retain this literature for any future reference Remind the user that in order to comply to the regulati...

Страница 17: ...ts prevention Make sure the flame extinguishes after the use Check the soundness of the gas connections with a soap solution If a gas leack should be detected open immediately the windows and don t switch on or use electrical appliances or connect or disconnect plugs from sockets because flames or sparks can provoque explosions If the flame is instable stop using the water heater and call an autho...

Страница 18: ... the most convenient type of shower head multi func tion in order to obtain the best results in terms of temperature and quantity of water 4 3 ORDINARY MAINTENANCE Freezing prevention In case of extended periods of operation below zero it is suggested 1 Close the cold water tap 2 Rotate the draining valve E and remove it re position it when all the remaining water has been completely drained E PRE...

Страница 19: ...l the service works have been done perform always the following operations Open the cold water inlet cock if previously closed Open the gas gate valve Ascertainn the gas and water soundness of the piping Refit the casing front panel 5 INSPECTION AND MAINTENANCE 6 ERROR CODES Table Anomalies prospect Instructions for inspection and main tenance In order to assure for long time the correct operation...

Страница 20: ...ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Отзывы: