User’s operating instructions

Maintenance

- Clean monthly the water inlet filter.
- Always make sure there are no water leaks.
- Ask a professionally qualified technician for an inspection

to the burner, the evacuation system.

- Inspect always the flame inside the water heater for detec-

ting possible anomalous conditions.

- The gas valve is operated by the water pressure; if the wa-

ter pressure is below 0,5 bar the water heater cannot work.

- The safety valve drips when the water pressure is too

high: it will release somme drops in order to reduce the
pressure and protect the water heater.

- When more water drawings are contemporaneous (2 or 3

taps open at the same time) the flow rate of each tap can be
reduced or the temperature can decrease.

- The formation of white plumes, with low outer temperature,

is normal (white smoke).

-

When the outlet water temperature is too high:

- Reduce the temperature by acting on the selector 

’D’’

 of

FLAME OUTPUT; if this is not enough increase the flow
rate by acting on the adjuster ’’C’’ (WATER FLOW RATE).

-

When the outlet water temperature is too low:

- Increase the temperature by acting on the selector 

‘’D’’

 of

FLAME OUTPUT; if this is not enough reduce the flow
rate by acting on the adjuster ’’C’’ (WATER FLOW RATE).

- Select the most convenient type of shower head (multi-

func tion) in order to obtain the best results in terms of
temperature and quantity of water.

4.3 - ORDINARY MAINTENANCE

Freezing prevention

In case of extended periods of operation below
zero, it is suggested:
1 - Close the cold water tap.
2 - Rotate the draining valve 

‘‘E‘‘

 and remove it;

re-position it when all the remaining water has
been completely drained.

E

PRECAUTIONS:

When taking a shower, in order to avoid scorches, make

sure the water temperature is at an acceptable value.

After using water at high temperature, in order to avoid

scoches at the next use, adjust the  water temperature at an
acceptable value.

The dust, in time, could cause the lockout of
the water heater and compromise the combus-
tion with increase of the carbon monoxide. It is
then necessary to call a qualified technician
for cleaning and remove the dust  and soot
every six months in order to make sure the
combustion products are evacuated regularly.

The water heater must be installed vertically.

Behaviour in anomalous conditions

In case of noisy combustion, smoke at the out-
let or poor combustion, close the gas gate val-
ve, switch off the appliance and contact the
service center.

Prevention of scald injury (if the casing is
removed)

The qualified technician , after removing the
casing, must check the flame via the sight
glass.
During this operation it is important to take care
and stay at a minimum distance of  300mm.

Содержание IDRONIK TN 14

Страница 1: ...00333640 2nd edition 04 2011 INSTRUCTIONS FOR INSTALLER USER AND SERVICE MAN IDRONIK TN 14 Instantaneousgas water heater type B ...

Страница 2: ...e user 3 1 5 Safety warnings 4 1 6 Data badge 5 1 7 Guarantee condizions 5 1 8 General warnings 6 2 TECHNICAL FEATURES AND DIMENSIONS 7 2 1 Technical features 7 2 2 Dimensions 7 2 3 Main components 8 2 4 Operational data 8 2 5 General features 8 3 INSTRUCTIONS FOR THE INSTALLER 9 3 1 General warnings 9 3 2 Installation standards 10 3 3 Packaging 10 3 4 Water heater location 11 3 5 Water heater ins...

Страница 3: ...e it is recommended to adjust the domestic hot water temperature as near as possible to the one you really require We recommend you to check the state of cleanliness of the heat exchanger at the end of the first year and subsequently on the basis of the lime scale found this period can be extended to two years 1 4 INFORMATIONS TO BE HANDED OVER TO THE USER 1 GENERAL INFORMATION The user has to be ...

Страница 4: ...r loosening the screw pipe connections use only adequate fork spanners The improper use and or the use of inadequate equipment can cause damages for example water or gas leakages WARNING Indications for appliances operating with propane gas Ensure yourself that before installing the appliance the gas tank has been purged For a correct purging of the tank contact the liquid gas supplier or a compet...

Страница 5: ...ass A Features of the D H W circuit 7 Pn Nominal Output 8 Qmax Nominal max input 9 PW Max D H W Working Pressure 10 T max Max D H W Working Temperature B Electrical Data 11 Electrical supply 12 Electrical consumption 13 Protection degree C Factory settings 14 Adjusted for gas type X D Destination countries 15 Direct and indirect destina tion countries 16 Gas category 17 Feeding pressure 18 Space f...

Страница 6: ...of the ON OFF switch and or by means of the appropriate shutdown devices In the event of failure and or faulty functioning of the appliance switch off the appliance Do not attempt to make any repairs contact qualified technicians Any repairs must be carried out by Unical authorized technicians and using only original spare parts Non observance of the above requirement may jeopardize the safety of ...

Страница 7: ...y II2H3P The gas water heater IDRONIK TN is complete with all the safety and control devices foreseen by the relevant Standar ds Furthermore it complies with Gas Appliances Directive 2009 142 EC ElectroMagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC 2 TEHNICAL FEATURES AND DIMENSIONS 2 2 DIMENSIONS COMPONENTS DESCRIPTION Atmospheric burner Ultraflat wet chamber heat e...

Страница 8: ...put Nominal output Pn Minimum output Efficiency at nominal load Efficiency at partl load Gas type Category Nominal gas feeding pressure Burner nozzle N Off Burner nozzle Ø Smoke evacuation type kW kW kW kW mbar mm IDRONIK TN 14 2 3 MAIN COMPONENTS 1 D H W outlet1 2 2 Gas valve 3 Burner 4 Heat exchanger 5 Combustion chamber 6 Flue outlet Ø 120 7 Ignition ionisation electrode 8 Flow switch 9 Batteri...

Страница 9: ... other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The connection between the boiler and chimney flue outlet can be made only after this verification has been carried out WARNING In rooms where aggressive vapours or dust are present the appliance must operate independently from ...

Страница 10: ...anty card Nr 2 spare parts request coupons DO NOT DISPERS IN THE ENVIRONMENT A 450 B 825 C 210 3 2 STANDARD CODES FOR INSTALLA TION IDRONIK TN is of the gas category II2H3P The appliance must be installed in compliance to the instructions contained in this manual The installation must be carried out by a competent qualified engineer whom will assume the esponsibility of complying to all the local ...

Страница 11: ...g with the gas type available This is verifiable via the indication on the packaging and on the data badge c Check that the chimney flue pipe has an adequate draught does not have any constrictions and that no other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The connection betw...

Страница 12: ...fore installing the boiler it is recommended to thoroughly clean all the fuel feed pipework in order to remove any eventual residual grime which could compromise the boilers correct functioning If you smell gas a Do not turn on or off electrical switches use the telephone or any other object which can provoke sparks b Open all doors and windows in order to allow fresh air to enter and purify the r...

Страница 13: ...room is not a bed room The adjacent room is not a common part of the building and is not a room with fire danger e g a fuel deposit a garage etc 3 9 FLUE GAS DISCHARGE SYSTEM Connection to the chimney A good chimney is very important for the correct functioning of the boiler it must therefore conform with the following requirements it must be made from waterproof material and be resistant at the t...

Страница 14: ...for the installer 2 Ø min Slope min 3 Ø 1 5 m min 2 Ø 1 m max 1 5 m min 2 Ø Ø Slope min 3 1 m max 2 Ø min 3 Ø 3 Ø DIMENSIONS FOR THE CONNECTION OF THE SMOKE EVACUATION DUCT MINIMUM CLEARANCES 150 150 200 Ø 120 71 200 ...

Страница 15: ...uch the appliance with any wet part of your body and or barefooted Do not pull the supply cables Do not expose the boiler to sunlight rain etc unless it is explicitly foreseen Do not permit children or inexpert people to use the appliance Ignition battery housing The appliance doesn t need to be connected to the electrical supply 230V It is fed by two 1 5 V batteries type D LR20 E95 AM1 ...

Страница 16: ...ormations to be passed on to the user The user must be instructed on the use and operation of his water heater and in particular Hand over to the end user this manual as well as all the other literature relative to the appliance and placed in the envelope contained in the packaging The user must retain this literature for any future reference Remind the user that in order to comply to the regulati...

Страница 17: ...ts prevention Make sure the flame extinguishes after the use Check the soundness of the gas connections with a soap solution If a gas leack should be detected open immediately the windows and don t switch on or use electrical appliances or connect or disconnect plugs from sockets because flames or sparks can provoque explosions If the flame is instable stop using the water heater and call an autho...

Страница 18: ... the most convenient type of shower head multi func tion in order to obtain the best results in terms of temperature and quantity of water 4 3 ORDINARY MAINTENANCE Freezing prevention In case of extended periods of operation below zero it is suggested 1 Close the cold water tap 2 Rotate the draining valve E and remove it re position it when all the remaining water has been completely drained E PRE...

Страница 19: ...l the service works have been done perform always the following operations Open the cold water inlet cock if previously closed Open the gas gate valve Ascertainn the gas and water soundness of the piping Refit the casing front panel 5 INSPECTION AND MAINTENANCE 6 ERROR CODES Table Anomalies prospect Instructions for inspection and main tenance In order to assure for long time the correct operation...

Страница 20: ...ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Отзывы: