Mode selection
OFF
If you are going away for prolonged period (also see
Holiday Function) or if you simply want to switch off
the heating, press the button and the sym-
bol is displayed. The heating is switched off, and
switched on again only if the room temperature falls
below 5°C: freezing protection function.
If equipped with a hot water tank, the boiler will not
deliver domestic hot water; instant-type hot water
boilers will deliver hot water.
SUMMER
To switch off the heating while maintaining the dome
-
stic hot water function, press the button and
the symbol is displayed.
The heating is switched off, and switched on again
only if the room temperature falls below 5°C: freezing
protection function.
Whatever the type of boiler, it will deliver hot water.
WINTER
To reactivate heating and restore the previously set
operation mode, press the button again and
the symbol will appear on the display.
Whatever the type of boiler, it will deliver hot water.
PROGRAMS
Heating AUTOMATIC operation (in Winter mode)
Press the button and the symbol will appear
on the display.
The Remote Control will function according to the
automatic weekly programme, displaying the 6 time
bands: the time band active at that moment is di-
splayed in a box.
If the box is not shown, this means that the current
time is between 00:00 hours and the start of time
band 1.
Set temperature level exclusion
In automatic mode the room temperature value can
be temporarily changed by pressing the buttons
in 0.1°C increments. By keeping the button
pressed the temperature will change rapidly. The
exclusion function, indicated on the display by the
symbol time band change.
Heating MANUAL operation (in Winter mode)
To use Remote control at a fixed room temperature
level, press the button the symbol appears
on the display (the 6 time bands are not displayed).
Then set the room temperature value by pressing
the buttons in 0.1°C increments. By keeping
the button pressed the temperature will change ra-
pidly. Manual mode will be maintained until another
operation mode is selected.
Test
Follow the instruction given below to activate
test procedure
1. Press the middle button of the Bridge
The heating demand is activated for 30 seconds with
maximum set.
The left LED lights up for 2 seconds to indicate that
there is communication. Otherwise, see the point 3
of the ‘‘CONFIGURATION AND ACTIVATION’’.