Other function
Information menu
The remote control can provide the user with information on boiler status. Each press of the button allows
the cyclic display of the following information:
T1 - Heating circuit delivery water temperature
T2 - Domestic hot water temperature
T3 - Heating circuit return water temperature (boilers with sensor only)
T4 - Delivery water temperature setpoint calculated by the remote control
P5 - Actual burner power
F6 - Actual fan speed (condensing boilers only)
F7 - Actual DHW flowrate (instant hot water boilers with flowmeter only)
P8 - Actual system pressure (boilers with pressure sensor only)
v - Remote control software version
Press any other button to exit the menu.
Power Failure
In this case the Bridge RF stops working, because it is electrically fed by the boiler card. The symbol ( )
shown on the Remote Control display starts flashing. If the power is restored within 2 minutes, the symbol
becomes fixed again and RF communication is immediately activated. Otherwise the display activates
fault E94 and the symbol : once the power is restored, it is necessary to wait 15 minutes. After which
the symbol becames fixed and RF communication is avaible again.
Diagnostic
The remote control constantly monitors boiler staus and signals any faults by activating an alarm icon and
specific fault code: for a description of the fault, refer to the boiler documentation. Certain faults cause per
-
manent shutdowns (indicated with the letter “A”): to reinstate operation just press the RESET button; other
faults (indicated with the letter “F”) cause temporary shutdowns which are automatically reset as soon as
the value returns within the boiler’s normal working range.
Room temperature probe fault
In case of a Remote Control room temperature probe, the display activates fault code E92 and the
symbol . Heating is switched off.
External temperature probe fault
In Sliding Temperature operation and in case of an external temperature probe (optional) fault, the display
activates fault code E93 and the symbol . The adjustment temperature become fixed at the ‘‘Heating
temperature adjustment’’ value. To eliminate the fault, reset the external probe or disable Sliding Tempe-