![Unical EASYr Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/unical/easyr/easyr_installation-servicing-and-users-manual_3718630007.webp)
7
ENGLISH
6
User guide
1 Installation check (Bridge)
Make sure the bridge is electrically fed through the
connection with the boiler card.
Comunication EASYr Bridge (left led)
OK COMUNICATION
1 flashing every 3 sec.
NO COMUNICATION
3 fast flashing every 2 sec.
2 Installation battery (EASYr)
Note: Follow the instruction in this section only for
the first installation of EASY
r or if the EASYr display
shows the symbols or numbers appears)
a. Remove the front cover by prising with a
screwdriver at points
b. Insert two 1,5V AA LR6 batteries, making
sureto fit them in the right direction.
c. Refit front panel of EASY
r.
d. Wait: finding automatic syncronism between
EASYr and Bridge.
3. Setting the time and day
a. Press the button
The day starts flashing:
use the button
to set the correct day of the week, where DAY 1
is monday and DAY 7 is sunday.
b. Press the button
Hours starts flashing:
use the button
to set the correct hours from 00 to 23.
c. Press the button
Minutes starts flashing:
use the button
o set the correct minutes from 00 a 59.
d. Press the button
Synchronization (EASYr e BRIDGE)
Note: During installalion,it is recommended to supply
the Bridge before EASYr so that this searches the
synchronization with the base when this one is
already working.
The kit comes already associated,so the EASYr will
begin immediately the search of synchrony. This is
showed by the symbol ; flashing for max 2 minu
-
tes and when it stops, the synchrony has occurred lf
there is no communlcation and the error E94 appears
the system will retries automatically synchrony every
15 minutes.
What you can do lf there is not communl-
cation:
a.
Make sure the Bridge is electrically supplied
through the connection with the boiler card (see
step 1).
b. Bring EASYr nearer the Bridge
c. Wait: Finding automatic synchronism between
EASYr and Bridge.
lf after completing the above steps there is no syn-
chrony, symbol flashing, remove and reinsert the
batteries from the Remote Control.
Wait for search of communlcatlon.
lf the problems remain, see:
EASYr - BRIDGE ASSOClATION.
Configuration and Activation
EASYr - BRIDGE ASSOCIATION
The kit comes already associated, the process
1. Keep the button pressed for 10 sec.
2. The display shows LINK window.
3. If you see “dE” devices are not associates
(the middle numbero indicates the local ad-
dress)
4. If you do NOT want to make any changes
press the button again.
4b Press the buton to diassociate devices.
5. The display shows “In”, the devices are not
associated (the middle number 0 blinks)
6. Press the middle button of the Bridge for 5
seconds. (the left LED blinks)
7. Press the Remote buton
8. The display shows >> for a few seconds
9. If you see “dE”, devices are associated (the left
LED of the bridge blinks)
9b. If the display shows “In” the devices are not
associated and you must start the process from
step 6
10. Press the button to exit.