Unical EASYr Скачать руководство пользователя страница 7

7

ENGLISH

6

User guide

 
1  Installation check (Bridge) 

Make sure the bridge is electrically fed through the 

connection with the boiler card. 

Comunication EASYr Bridge  (left led)

OK COMUNICATION   

1 flashing every 3 sec.

NO  COMUNICATION 

3 fast flashing every 2 sec. 

2  Installation battery (EASYr)

Note: Follow the instruction in this section only for 

the first installation of EASY

r  or if the  EASYr display 

shows the symbols         or numbers appears)

 
a.  Remove the front cover by prising with a 

   screwdriver at points

b.  Insert two 1,5V  AA LR6 batteries, making 

   sureto fit them in the right direction. 

 c.  Refit front panel of EASY

r. 

d.  Wait:  finding  automatic  syncronism  between   

 EASYr and  Bridge.

3. Setting the time and day

a.  Press the button   

 

  The day starts flashing: 

  use the            button      

  to set the correct day of the week, where DAY 1 

is monday and DAY 7 is sunday.

b.  Press the button     

  Hours starts flashing:

  use the            button 

  to set the correct hours from 00 to 23.

c.  Press the button 

  Minutes starts flashing:

  use the            button 

  o set the correct minutes from 00 a 59.

d.  Press the button 

 Synchronization  (EASYr e BRIDGE)

Note: During installalion,it is recommended to supply 

the Bridge before EASYr so that this searches the 

synchronization with the base when this one is

already working.

The kit comes already associated,so the EASYr will 

begin immediately the search of synchrony. This is 

showed by the symbol      ; flashing for max 2 minu

-

tes and when it stops, the synchrony has occurred lf 

there is no communlcation and the error E94 appears 

the system will retries automatically synchrony every 

15 minutes.

What you can do lf there is not communl-

cation:

a. 

Make sure the Bridge is electrically supplied  

  through the connection with the boiler card (see  

  step 1).

b.  Bring EASYr nearer the Bridge

c.  Wait: Finding automatic synchronism between  

 EASYr and Bridge.

lf after completing the above steps there  is no syn-

chrony,      symbol flashing, remove and reinsert the 

batteries from the Remote Control.

Wait for search of communlcatlon.

lf the problems remain, see: 

EASYr - BRIDGE ASSOClATION.

Configuration and Activation

EASYr - BRIDGE ASSOCIATION

The kit comes already associated, the process

1.  Keep the button         pressed for 10 sec.

2.  The display shows LINK window.

3.  If you see “dE” devices are not associates  

  (the middle numbero indicates the local ad- 

 dress)

4.  If you do NOT want to make any changes  

  press the button        again.

4b  Press the buton        to diassociate devices.

5.  The display shows “In”, the devices are not 

   associated (the middle number 0 blinks)

6.  Press the middle button of the Bridge    for 5  

  seconds. (the left LED blinks)

7.  Press the Remote buton 

8.  The display shows  >> for a few seconds

9.  If you see “dE”, devices are associated (the left  

  LED of the bridge blinks)

9b. If the display shows “In” the devices are not  

   associated and you must start the process from  

  step 6

10. Press the button         to exit.

Содержание EASYr

Страница 1: ...E N G L I S H REMOTE CONTROL ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL...

Страница 2: ...e instructions contained in the manuals supplied with the boiler Index 1 Genera features 3 2 Package Contents 3 3 Description buttons and symbols 3 4 Application 5 5 Installation 6 6 Easy User Guide 7...

Страница 3: ...ogramming 0 Deactivated P2 Pre Heating Function 0 Deactivated P3 Max number of daily time bands 6 P4 Heating min temperature P5 Filling the system 0 Deactivated P6 Temperature unit of measure selectio...

Страница 4: ...Manual room temperature increase button BRIDGE 1 TEST mode button 2 LED behind the button DISPLAY KEY 11 Heating programme time bands 12 Day of week 13 Holiday function button copy heating DHW program...

Страница 5: ...5 E N G L I S H Connect the Bridge to the TA1 OT ter minals of the boiler after removing the jumper from TA2 4 Application Bridge can be hidden inside the boiler...

Страница 6: ...RF Bridge by prising with a screwdriver at A e B Then fix the back of the bridge to the wall with the set of screws supplied running the two wires inside the rectangular hole at the bottom near the t...

Страница 7: ...ediately the search of synchrony This is showed by the symbol flashing for max 2 minu tes and when it stops the synchrony has occurred lf there is no communlcation and the error E94 appears the system...

Страница 8: ...Control will function according to the automatic weekly programme displaying the 6 time bands the time band active at that moment is di splayed in a box If the box is not shown this means that the cur...

Страница 9: ...utes increments By keeping the button presses the hours will change rapidly 3 Press the button The room temperature inside the house starts flashing use the buttons to change the temperature level in...

Страница 10: ...utton associated with a different operation mode Telephone contact input GSM Normal Remote Control operation is ensured as long as the telephone contact remains open The closing of this contact indica...

Страница 11: ...button pressed for 3 seconds 2 The display shows the CU parameter Press the buttons to modify the compen sation curve by increments of 1 unit By keeping the button pressed the value will change rapidl...

Страница 12: ...same day so that the room temperature set by the user is reached at the start of the programmed time band The Remote Control calculates an initial hypothetical Pre activation time if the programmed r...

Страница 13: ...The display shows parameter P5 Set to 0 using the buttons to deactivate the electric filling device Set to 1 using the buttons to activate Automatic system filling 5 Press any other button to exit the...

Страница 14: ...display activates fault E94 and the symbol once the power is restored it is necessary to wait 15 minutes After which the symbol becames fixed and RF communication is avaible again Diagnostic The remo...

Страница 15: ...15 E N G L I S H...

Страница 16: ...erves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics 46033 casteldario mantova italia tel 39 0376 57001 f...

Отзывы: