26.1 Emergency measures when crane will not function at all
1)
Check that all manual levers are at their neutral positions.
2)
Re-start the engine and wait for 2seconds to operate the crane.
3)
Hasnʼt the emergency stop switch been depressed?
Reset the emergency stop switch to operate the crane.
4)
Please store the crane
while resetting overwinding automatic stop switch.
5)
Please store the crane
while resetting Controlbox reset switch.
6)
Unfasten the hexagon nut by 3 turns with the
set bolt locked with a screwdriver.
Tighten up the set bolt fully while paying attention
that the hexagon nut will not be turned together
with the set bolt.
Lock the set bolt with the hexagon nut to prevent
it from being loosened.
This allows the crane to be operated by manual control but the
automatic stop for over-winding will not function
7)
Extract the lock pin with your hand to screw in
the emergency screw and disconnect the power
connector, “BATTERY MAIN”.
Although both the automatic stop for over-winding and
the auto acceleration will not function, this allows the
crane to be operated by manual control.
If the crane can be operated by taking
measures described in sections 4) and 5) above,
contact local UNIC crane sales agent or
service shop immediately as the crane is faulty.
Emergency screw
( 26 - 1 )
Содержание URW295CR
Страница 1: ...MAINTENANCE MANUAL FURUKAWA UNIC CORPORATION URW295CR ...
Страница 36: ... 9 5 9 5 Back pressure valve O ring 731191018 Back pressure valve Gauge port ...
Страница 94: ... QQO VQR KP FGVCKN ...
Страница 100: ... 9 4 412 4 6 0 0 0 5 KOKV UYKVEJ ...
Страница 124: ... 㧟㧞 ...
Страница 125: ... ...