26.3 How to judge differential transformer (750211003) for
break or short-circuit of coil
In order to prevent the differential transformer from being broken, use a circuit tester with digital
display when checking it.
When differential transformer coil beaks or short-circuits:
No crane operation can be possible.
Voice message ”Service remote control” sounds.
Mode indicator lamp on the control box blinks to show where in trouble.
Mode
indication
Area in trouble
80
Derrick
81
Hoist
82
Telescoping
83
Slewing
84
Outrigger
85
Accelerator
How to check differential transformer:
① Measure resistance between each combination of terminals.
If any of measured resistance shows a big difference, replace the transformer.
Terminals between
Resistance
1←→2
24Ω
3←→4
64Ω
3←→5
32Ω
⑤Blk
③Grn
①Yel
4←→5
32Ω
―
―
―
Not used
―
―
④Blu
②Wht
32Ω
24Ω
Terminal arrangement of connector of
differential transformer
64Ω
32Ω
Mode indicator
( 26 - 3 )