46
ERROR
CODE
COMPONENTS AFFECTED
POSSIBLE CAUSES
CONSEQUENCES
SAFETY EXIT
CONDITIONS
34
DO3
UNIT 3 dosing
unplugged, no signal:
- Check the component and
wiring
Manual dosing alarm
Automatic if defect
removed
35
DO3
UNIT 3 dosing
short circuited:
- Check the component and
wiring
Manual dosing alarm
Automatic if defect
removed
36
DO3
UNIT 3 dosing
Interruption of counting
for more than 5 seconds: -
Check free rotation of the
dispenser turbine and cabling
(defective contact)
Dosing alarm or Manual stop
Automatic if defect
removed
37
DO3
UNIT 3 dosing
Infusion time longer than 110
seconds, flow too weak:
- Check the cleanliness of the
water circuit or coarsen the
grind.
Infusion cycle stopped
Automatic if defect
removed
38
EH3
UNIT 3 DOSAMAT
sensor
Unplugged, no signal:
- Check the component and
wiring
Manual dosing alarm
Automatic if defect
removed
39
EH3
UNIT 3 DOSAMAT
sensor
Short circuited:
- Check the component and
wiring
Manual dosing alarm
Automatic if defect
removed
50
DOE
HOT WATER dosing
Unplugged, no signal:
- Check the component and
wiring
Manual dosing alarm
Automatic if defect
removed
51
DOE
HOT WATER dosing
Short circuited:
- Check the component and
wiring
Manual dosing alarm
Automatic if defect
removed
52
DOE
HOT WATER dosing
Interruption of counting
for more than 5 seconds: -
Check free rotation of the
dispenser turbine and cabling
(defective contact)
Dosing alarm or Manual stop
Automatic if defect
removed
53
DOE
HOT WATER dosing
Cycle time longer than 110
seconds, flow too weak: -
Check the cleanliness of the
water circuit.
Cycle stop: EVE
Automatic if defect
removed
54
STS
StreamAir probe
Unplugged, no signal: -
Check the probe and wiring
Alarm, Manual Start
Automatic if defect
removed
55
STS
StreamAir probe
Short circuited: - Check the
probe and wiring
Alarm, Manual Start
Automatic if defect
removed
56
STS
StreamAir probe
Value outside the authorised
range:
- Check the programmed
value and the probe.
Alarm, Manual Start
Automatic if defect
removed
57
CP1
UNIT 1 Pressure
sensor
Unplugged, no signal:
- Check the sensor and wiring
Alarm
Automatic if defect
removed
58
CP1
UNIT 1 Pressure
sensor
short circuited: - Check the
sensor and wiring
Alarm
Automatic if defect
removed
59
CP1
UNIT 1 Pressure
sensor
Value outside the authorised
range:
- Check the programmed
value and the sensor.
Alarm
- Sensor not taken into
account
- Setpoint pressure replaced
by time lag (see coffee cycle
with pre-infusion)
Automatic if defect
removed
60
CP2
UNIT 2 Pressure
sensor
Unplugged, no signal:
- Check the sensor and wiring
Alarm
Automatic if defect
removed
61
CP2
UNIT 2 Pressure
sensor
short circuited: - Check the
sensor and wiring
Alarm
Automatic if defect
removed