45
ERROR
CODE
COMPONENTS AFFECTED
POSSIBLE CAUSES
CONSEQUENCES
SAFETY EXIT
CONDITIONS
16
DO1
UNIT 1 dosing
Interruption of counting
for more than 5 seconds: -
Check free rotation of the
dispenser turbine and cabling
(defective contact)
Manual dosing alarm
Automatic if defect
removed
17
DO1
UNIT 1 dosing
Infusion time longer than 110
seconds, flow too weak:
- Check the cleanliness of the
water circuit or coarsen the
grind.
Infusion cycle stopped
Automatic if defect
removed
18
EH1
UNIT 1 DOSAMAT
sensor
Unplugged, no signal:
- Check the component and
wiring
Manual Start alarm
Automatic if defect
removed
19
EH1
UNIT 1 DOSAMAT
sensor
Short circuited:
- Check the component and
wiring
Manual Start alarm
Automatic if defect
removed
20
TS2
UN2 safety thermostat
Started due to overheating:
- Check the SR2 regulation
circuit and TS2 thermostat
(manual reset)
Unit 2 heating stopped - BG2
box on standby
Defect removed and
manual reset of TS2
and machine reset
21
SR2
UNIT 2 thermostatic
probe
Unplugged, no signal:
- Check the probe and wiring
Unit 2 heating stopped - BG2
box on standby
Defect removed and
Machine reset
22
SR2
UNIT 2 thermostatic
probe
Short circuited:
- Check the probe and wiring
Unit 2 heating stopped - BG2
box on standby
Defect removed and
Machine reset
23
SR2
UNIT 2 thermostatic
probe
Value outside the authorised
range:
- Check the programmed
value and the probe.
Unit 2 heating stopped - BG2
box on standby
Automatic if defect
removed
24
DO2
UNIT 2 dosing
Unplugged, no signal:
- Check the component and
wiring
Manual dosing alarm
Automatic if defect
removed
25
DO2
UNIT 2 dosing
short circuited: - Check the
component and wiring
Manual dosing alarm
Automatic if defect
removed
26
DO2
UNIT 2 dosing
Interruption of counting
for more than 5 seconds: -
Check free rotation of the
dispenser turbine and cabling
(defective contact)
Dosing alarm or Manual stop
Automatic if defect
removed
27
DO2
UNIT 2 dosing
Infusion time longer than 110
seconds, flow too weak:
- Check the cleanliness of the
water circuit or coarsen the
grind.
Infusion cycle stopped
Automatic if defect
removed
28
EH2
UNIT 2 DOSAMAT
sensor
Unplugged, no signal:
- Check the component and
wiring
Manual Start alarm
Automatic if defect
removed
29
EH2
UNIT 2 DOSAMAT
sensor
Short circuited:
- Check the component and
wiring
Manual Start alarm
Automatic if defect
removed
30
TS3
UN3 safety thermostat
Started due to overheating:
- Check the SR3 regulation
circuit and TS3 thermostat
(manual reset)
Unit 3 heating stopped
BG3 box on standby
Defect removed and
manual reset of TS3
and machine reset
31
SR3
UNIT 3 thermostatic
probe
Unplugged, no signal:
- Check the probe and wiring
Unit 3 heating stopped
BG3 box on standby
Defect removed and
Machine reset
32
SR3
UNIT 3 thermostatic
probe
Short circuited:
- Check the probe and wiring
Unit 3 heating stopped
BG3 box on standby
Defect removed and
Machine reset
33
SR3
UNIT 3 thermostatic
probe
Value outside the authorised
range:
- Check the programmed
value and the probe.
Unit 3 heating stopped
BG3 box on standby
Automatic if defect
removed