Automatic measurement of voltage parameters
:
Customised parameters are for quick parameter
measurement. The measurement menu of your
oscilloscope is capable of measuring 26 waveform
parameters. Two of them (delay and phase for
advance measurement) are generally used when you
do not require to measure all parameters but only a
few. You can set these as customized parameters.
Customized parameters are displayed on the screen.
Your UTD4000
Series Oscilloscope
can automatically measure the following voltage
parameters :
Peak-to-peak value (Vpp) : The voltage value from the
highest point to lowest point of the waveform.
Maximum value (Vmax) : The voltage value from the
highest point to ground (GND) of the waveform.
Minimum value
Vmin
The voltage value from
the lowest point to ground
GND
of the waveform
Amplitude value (Vamp) : The voltage value from top
to base of the waveform.
Mean (Vmid)
Half of the amplitude value.
Top value (Vtop) : The voltage value from the level top
to ground (GND) of the waveform.
Base value (Vbase) : The voltage value from the level
base to ground (GND) of the waveform.
Overshoot : The ratio value of the difference between
maximum value and top value to the amplitude value.
(
) :
(
)
.
:
Four-channel
Figure 2-27 Measurement parameters
72