UTD4000 Four-channel User Manual
48
Table 2-16 Slew rate setup
Function Menu
Setup
Explanatory Note
When
Trigger occurs when the signal slew rate within the threshold is
greater than the set slew rate
Trigger occurs when the signal slew rate within the threshold is
smaller than the set slew rate
Trigger occurs when the signal slew rate within the threshold
equals to the set slew rate
<
>
=
Polarity
Select the rising edge within the threshold for trigger
Select the falling edge within the threshold for trigger
Rise
Fall
Slew rate
Set the slew rate value with the
control knob
MULTIPURPOSE
Threshold
Low
High
High & Low
Change the low level value with the
control knob
Change the high level value with the
control knob
Change the high and low level value with the
control knob
MULTIPURPOSE
MULTIPURPOSE
MULTIPURPOSE
Back
Return to the slew rate trigger menu
Alternate Trigger
When alternate trigger is selected, the trigger signal will be present in two vertical channels. This triggering
mode is suitable for observing two signals of unrelated signal frequencies
Alternate trigger can also be
used to compare pulse widths
.
.