No. 47800-2-02-5
➨
To check the valves use a hex key to remove eight socket-
head screws from the pump head and remove the housing
cover with head cover, valves and O-rings.
☞
Never remove parts by using a spiky or sharp-edged tool
(e.g. screw driver), we recommend to use a rubber mallet
or compressed air (to be blown
carefully
into port).
➨
Remove the head cover carefully from the housing cover.
Note the position of the valves and remove them.
☞
Replace valves if necessary.
☞
Use petroleum ether or industrial solvent to remove de-
posits. Do not inhale.
Cleaning and inspecting the pump heads
➨
Position the pump on the side. Support pump appropriately if necessary. Open only one side of the
pump at a time.
1: Housing cover
2: O-rings (not ME 8 NT)
3: Valves
4: Head cover
5: Diaphragm clamping disc
with square head screw
Pump head parts:
6: Diaphragm
7: Diaphragm support disc
8: Washer
9: Connecting rod
10: Housing
11: Connecting tube with O-ring
2
9
4
10
8
6
7
5
3
1
11