3. Installation and Storage 

3.1  Cautions for Installation and Storage

 

 

See Warning 
(1)(2)(3)(5)(6)(7)(8)(9)(10)(11)(12)(13), P04

 

 

See Caution (1)(2)(3), P05

 

 

See Note (1)(2)(3)(4), P06 

 
3.2  Environmental Conditions for Installation, Storage, and Operation 
 

The fine clearances used in this pump require that the following conditions be satisfied during 
storage, installation, and operation. 
 
1.  Ambient temperature of 7~40°C and maximum relative humidity of 85% during operation. 
2.  Other conditions (during storage and operation). 

a) Level floor of sufficient strength. 
b)  No condensation 
c)  Dust-free environment 
d)  Well ventilated 
e)  Environment free of corrosive or explosive gas. 
f)  Not subject to direct sunlight. 
g) No danger of fire. 
h) Maximum ambient temperature of 40°C during assembly of pump. 
i) There is a space which is sufficient for pump surroundings, the pump cooling fan part is not 

covered. 

 

3.3  Location 

The  pump  should  be  installed  level  in  a  location with  minimal  dust  and  humidity. This  location 
should  be  selected  in  consideration  of  ease  of  installation  and  removal,  inspection,  and 
cleaning. 
Particular attention should be paid to ambient temperature when fitting the pump to equipment. 
Use  anti-vibration  rubbers  to  isolate  the  pump  from  vibrations  in  the  equipment.  See  3.2 
Environmental Conditions for Installation, Storage, and Operation for details. 

 
3.4  Electric Wiring 

(1)  The wire diameter of power cord must be 

φ

1.0mm or more. 

(2)  We recommend end-user to equip protection device such as earth leakage breaker motor 

breaker on electric wiring to prevent from motor burnout which may occur by overcurrent. 

(3) Be sure to ground to the screw next to the earth mark. 
    Please attach earth terminal as shown in Fig.3-1 
(4)  The  electric  wire  which  will  be  connected  to  the  earth must  be  a green colored  insulating 

coating wire, with or without yellow stripes. Its wire diameter must be 

φ

1.0mm or more. 

Notice: Before operating wire connection, be sure to unplug the power plug.   

 
 
 
 
 
 
 
 
 
 

 
 

!

Warning

 

!

Caution

 

!

Note 

M4×8+SW+PW 

Pump 
Earth Attaching Portion 

Toothed  Lock 
Washers. 

M4

 

Round Shape Earth Terminal.     
Please have it prepared by customer 

Fig.3-1

 

Instillation Method of Earth Screw 

 

Содержание DOP-40D

Страница 1: ...Users Please read this manual thoroughly to ensure safe and effective use of the equipment Keep this manual in a safe place Due to periodic improvements in performance the equipment described in this...

Страница 2: ...6 Checking Operation After Installation 4 3 7 Piping 5 3 8 Storage 5 4 Cautions for Operation 5 4 1 Cautions for Operation 5 4 2 Operation of the Thermal Protection Relay 5 4 3 Starting in Cold Weathe...

Страница 3: ...e and frequency 4 Fig 3 3 Example of Piping Used When Evacuating a Vessel 5 Fig 6 1 Cup packing attachment figure 10 Fig 6 2 Suction and exhaust valves attachment figure 11 Fig 6 3 Exploded View DOP 8...

Страница 4: ...pment correctly Read the section on Safe Use particularly closely Keep This Manual in a Safe Place After reading this manual be sure to keep it in a safe place which is readily accessible to others ne...

Страница 5: ...ws or inlet and outlet pipes loose Are any components missing Contact your agent or the sales division of the manufacturer if there are any problems with the pump 1 Ensure that the tube on the side of...

Страница 6: ...or Incorrect handling of the equipment may result in death or serious injury to the operator Incorrect handling of the equipment may result in light or medium injuries to the operator or damage to the...

Страница 7: ...and make sure that the pump has stopped before carrying out inspection and repair 5 Ensure that the relevant wiring is in accordance with technical standards for electrical equipment and wiring regul...

Страница 8: ...onents are discharged from the outlet and contaminate the room If necessary connect a pipe from the discharge outlet to the outside of the building 2 The fine clearances used in this pump require that...

Страница 9: ...lean air at normal temperatures or gases with equivalent characteristics 6 This pump is only for vacuum pumping 7 In addition to discharge of gas via the pump outlet gas may leak from the pump itself...

Страница 10: ...0 L min 80 L min 60Hz 44 L min 88 L min Pressure achieved 1 20 kPa 5 33 kPa Motor 1 210W 4P capacitor operation Rated current 50Hz 3 2A 3 15A 1 6A 1 4A 60Hz 3 9A 3 42A 1 7A 1 4A Rated Voltage 100V 115...

Страница 11: ...2 2 Dimensions Fig 2 1 DOP 40D Dimensions Fig 2 2 DOP 80S Dimensions...

Страница 12: ...is location should be selected in consideration of ease of installation and removal inspection and cleaning Particular attention should be paid to ambient temperature when fitting the pump to equipmen...

Страница 13: ...safe is maintained on practical use it means not resulting in the grade which shortens a life remarkably and the characteristic a temperature rise etc do not apply correspondingly in the state of rati...

Страница 14: ...main power supply and check that the pump has stopped Remove the power cord connected to the pump place the rubber caps over the inlet and outlet and store in a location with low humidity 4 Cautions...

Страница 15: ...vacuum gauge is mounted a distance from the pump the steam generated by water droplets and rust etc on the inside walls of the pump and piping and a variety of gases present in the system result in in...

Страница 16: ...ect consumables after the first 3000 hours of operation and replace and clean in accordance with the Guidelines for Replacement and Cleaning on the following page Refer to 6 4 Replacing Consumables an...

Страница 17: ...details Method of inspection Every 3000 hours Cup packing Abnormal wear hardening cracking Visual inspection Suction and exhaust valves Deformation hardening chipping Visual inspection O ring Deforma...

Страница 18: ...pump head covers back in place at torque of 5 0 N m Make sure the gaskets are securely inside the pump head cover gasket grooves and that there is no biting between the pump head covers and plates 2...

Страница 19: ...on the connecting rod and insert the cylinder by hand Place the retainer with the newly attached Suction valve rubber separator on top of the cup packings and fasten sealing anti loosening agent for...

Страница 20: ...t at 0 8 N m torque Next loosen the small cap head screws M3 5 and remove the suction valve and flat washers Wipe the pump head plates clean and replace the suction valves with new valves Lay the flat...

Страница 21: ...12 Fig 6 3 Exploded View DOP 80S...

Страница 22: ...essure correctly 5 1 Pressure does not diminish 3 Vacuum gauge is unsuitable 3 Measure with a calibrated vacuum gauge suitable for the pressure range 5 1 4 The inlet piping is too small in diameter or...

Страница 23: ...e and inspection etc d Malfunctions caused by modifications or repairs carried out by a party other than the manufacturer or by a service company not approved by the manufacturer e Malfunctions caused...

Страница 24: ...Industrial Safety and Health Law designates particular substances as the materials to be notified 2 Usage Status Operation Method Approx hours per day years and months Continuous Operation Intermitte...

Страница 25: ...6 6397 2286 ULVAC KIKO Inc https ulvac kiko com en Please contact us for products Service Base or other Inquiries from here ULVAC Inc Components Division 2500 Hagisono Chigasaki Kanagawa 253 8543 Japa...

Отзывы: