background image

 

 

18 

10. CONCLUSION 

This manual contains only general information about pump operation. Therefore, if you come up 

with any question or trouble, contact our representative or ULVAC KIKO. 

 

Warranty 

 

(1) The warranty for this pump (this equipment) extends for a period of one year from the date of shipment. 

(2) Any malfunctions or defects which occur under normal usage conditions during the warranty period will 

be repaired free of charge. 

Note, the warranty stated here is an individual warranty covering the pump. In addition, the scope of the 

warranty coverage concerning repairs is limited to the repair and/or replacement of parts. 

Normal usage conditions refer to the following: 

a) Ambient temperature and humidity during operation: 7 - 40

°

C, below 85% RH 

b) Operation in accordance with the user manual 

(3) Repair fees will incur during the warranty period for the following cases: 

a) Malfunctions due to a natural disaster or fire. 

b)  Malfunctions  caused  by  special  atmospheric  conditions,  such  as  salt  damage,  inflammable  gas, 

corrosive gas, radiation or pollution. 

c)  Malfunctions  caused  by  usage  conditions  that  differ  from  those  stated  in  the  user  manual 

(performance specifications, maintenance and inspection, etc.). 

d) Malfunctions caused by modifications or repairs carried out by a party other than the manufacturer, 

or by a service company not approved by the manufacturer. 

e) Malfunctions caused by noise (electric disturbance). 

f) Malfunctions that occur when not using a rated power supply. 

g)  Malfunctions  that  occur  when  there  is  an  abnormal  rise  in  internal  pressure  due  to  the  pump 

exhaust outlet being blocked during operation, etc. 

h) Malfunctions that occur, when the pump is damaged as a result of being dropped or falling, etc. 

i)  Malfunctions  which  are  determined  by  the  manufacturer

s  technical  personnel  to  be  caused  by 

conditions that do not comply with the usage conditions for this vacuum pump. 

j) Malfunctions due to the replacement of consumables.         

(4) Disclaimer 

a) We shall not be liable for any malfunctions of our products caused by the customer, regardless if 

the  malfunction  does  not  fall  within  the  warranty  period,  nor  shall  we  be  liable  for  any  loss  of 

opportunity for the customer

s clients or for compensation for any damages to other products, labor 

costs, production loss, transportation expenses and other related work.   

b) We shall not be liable for any claims and patent infringements, including secondary damages, filed 

a claim by a third party against the customer.

 

Содержание DA-20D Series

Страница 1: ...100V B 115V C 220V ULVAC KIKO Inc Request to Users Please read this manual thoroughly to ensure safe and effective use of the equipment Keep this manual in a safe place Due to periodic improvements in...

Страница 2: ...9 Compressors and vacuum pumps Safety requirements Part2 Vacuum pumps IEC EN 61010 1 2010 A1 2019 Safety requirement for electrical equipment for measurement control and laboratory use Part1 General r...

Страница 3: ...elated is in conformity with the following standards BS EN 1012 2 1996 A1 2009 Compressors and vacuum pumps Safety requirements Part2 Vacuum pumps BS IEC EN 61010 1 2010 A1 2019 Safety requirement for...

Страница 4: ...ON 10 7 CAUTIONS IN OPERATION 11 7 1 Cautions in Operation 11 7 2 Startup in Cold Season 11 7 3 Thermal Protector 11 7 4 Fluctuations in the power voltage and frequency 12 8 Maintenance Inspection and...

Страница 5: ...quipment correctly Read the section on Safe Use particularly closely Keep This Manual in a Safe Place After reading this manual be sure to keep it in a safe place which is readily accessible to others...

Страница 6: ...outlet caps fitted to inlet and outlet 2 3 Is the pump damaged in any way 4 Are any external screws or inlet and outlet pipes loose Are any components missing Contact your agent or the sales division...

Страница 7: ...uipment may result in death or serious injury to the operator Incorrect handling of the equipment may result in light or medium injuries to the operator or damage to the equipment Incorrect handling o...

Страница 8: ...ir the pump always note the gas which the pump has been used with on the Usage Check Sheet Note that if it has been used to discharge toxic gas for any reason it will be contaminated Please be aware t...

Страница 9: ...ectric shock 15 Touching electrical wiring etc while inserting the power plug may result in electric shock 16 The electric motor fitted to this pump incorporates a thermal protector however it is not...

Страница 10: ...g Not subject to direct sunlight h No danger of fire i When storing the pump or when operating it within other equipment ensure that the temperature in the vicinity of the pump does not exceed 40 C j...

Страница 11: ...operation Maintenance and Repair 13 Ensure that the pump is discarded in accordance with appropriate legislation related to the treatment and cleaning of waste products Ensure that the pump is discar...

Страница 12: ...ir 9 The pump is manufactured to accurate clearances and should not be dismantled or modified under any circumstances 10 Miscellaneous Problems e g faults with the vacuum pump shall be resolved by con...

Страница 13: ...9 5 DIMENSIONAL DRAWING Fig 1 DA 20D Fig 2 DA 40S...

Страница 14: ...d OFF connect the power cord to the power supply specified the motor rating 7 Turn ON the pump to check that pump is pumping 8 After that turn OFF the power to stop the pump 9 Make piping arrangement...

Страница 15: ...ssure If the pump is used for other applications consult with us 7 2 Startup in Cold Season In a cold season it may sometimes be difficult to start the pump due to hardened bearing grease diaphragm or...

Страница 16: ...nd to the voltage change and frequency change in Domain B it shall operate with main rated values and shall be used practically convenient However operation with it is convenient and safe is maintaine...

Страница 17: ...er s service division 8 2 Maintenance The following checks are required at least once every three days during operation If a problem is found take the measures described in 7 5 TROUBLESHOOTING 1 Check...

Страница 18: ...if hardening crack elongation or the similar is found Air filter Replace the air filter if dirt clogged hardening or the similar is found Bearing If grease runs out or unusual sound or vibrating sound...

Страница 19: ...ad cover Then remove the four hexagon socket head cap screws M6 20 and remove the pump head Remove a cross recessed head machine screws M3 5 remove pump head both sides and replace the suction exhaust...

Страница 20: ...16 Fig 4 Exploded view DA 40S...

Страница 21: ...um pressure Vent pump to atmospheric pressure Height above sea level during storage and installation 1000m or less Unusual sound 1 Bearing damaged Replace 2 Diaphragm broken Replace 3 Motor damaged Re...

Страница 22: ...anual performance specifications maintenance and inspection etc d Malfunctions caused by modifications or repairs carried out by a party other than the manufacturer or by a service company not approve...

Страница 23: ...Industrial Safety and Health Law designates particular substances as the materials to be notified 2 Usage Status Operation Method Approx hours per day years and months Continuous Operation Intermitte...

Страница 24: ...6 6397 2286 ULVAC KIKO Inc https ulvac kiko com en Please contact us for products Service Base or other Inquiries from here ULVAC Inc Components Division 2500 Hagisono Chigasaki Kanagawa 253 8543 Japa...

Отзывы: