19-2021 Rev E, 06/05/07
7
8. Select one side of the Main Support to start assembly of lamp modules. Begin
assembly of the Lamp Modules attachments first (see Figure 3b). Begin by installing
the Lamp Module furthest from the Power Junction Module location.
9. Thread the three wires from the last Lamp Module installed to the main extrusion
through the strain relief and into the wiring compartment of the next Lamp Module.
10. Route the external wires from the Lamp Modules into the Main Support wire raceway.
Attach Lamp Modules to the Main Support with supplied screws (4) as shown (See
Figure 3b).
Figure 3a
Figure 3b
11. Prepare next Lamp Module for attachment by removing wire access cover and
loosening strain-relief screws.
12. Thread the three wires from the last Lamp Module installed to the Main Support
through the strain relief and into the wiring compartment of the next Lamp Module.
13. Route the external wires from the Lamp Module under installation into the Main
Support wire raceway and attach next Lamp Module to support with four screws.
14. Tighten strain-relief screws to secure the external power wires
15. Cut, as required, and strip 3/8" from the wires and insert into respective WAGO
connector terminals (black-black, white-white, green-green)
16. Fold cables into Lamp Module enclosure and attach the wire access cover.
17. Repeat steps 5–14 as required until all Lamp Modules to be installed on the present
side of the Main Support are installed.
18. Proceed to install Lamp Modules to the second Lamp Module mounting side of the Main
Support.
19. Begin by installing the Lamp Module furthest from Power Junction Module. Repeat the
instructions included in steps 5 through 14.
Содержание High Output UV Device V-Flex
Страница 11: ...19 2021 Rev E 06 05 07 11...