12
GB
Faults
Cause
Remedy
Motor fails to start up
- No mains voltage
- Pump rotor blocked -thermostat
switched off
- Check voltage
- Dismantle and clean pump
No intake
- Intake valve not in water
- Pump chamber without water
connection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
- Max. suction height exceeded
- Immerse intake valve in water
- Fill water into intake
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate delivery rate
- Suction height too high
- Strainer dirty
- Water level falling rapidly
- Pump performance
diminishedby contaminants part
- Check suction height
- Clean strainer
- Immerse intake valve deeper
- Clean pump and replace
wearing
Thermostat switches pump off
- Motor overloaded - friction
caused by foreign substances
too high
- Dismantle and clean pump.
Prevent intake of foreign
substances (filter)
10.