PN 30A170 rev Jan2008
9
MODEL PAR30 GAS FRYER
F. OPERATING CONTROLS:
The “basic” PAR30 gas fryer is equipped with an Electronic Thermostat and Default-to-Manual-Restart (DTMR) control;
However customers may request the fryer be equipped with an “optional” Ultrastat Cooking Computer, such as an Ultrastat 11, 21
or 25 Cooking Computer. When applicable, operating instructions for the Ultrastat Cooking Computer will be provided with the
fryer. Operating controls on the Model PAR30 gas fryer include the Toggle
HEAT/OFF
Switch,
AMBER
Power Indicator Lamp,
RED
Burner Indicator Lamp, and the applicable Temperature Controller. These controls are mounted on the Temperature Control
Access Panel; and the Electronic Thermostat and other fryer controls are located behind the access door. The main drain valve and
shortening return levers are located behind the Service Access Panel. These controls were identified in the illustrations shown on
the previous page.
G. AUTOMATIC SAFETY FEATURES:
1. High limit thermostat to shut off gas to the main burners by opening a solenoid-actuated safety valve in the combination gas
control valve.
2. Combination gas control valve which includes a built-in pressure regulator and manual valve.
3. Sensing circuit within the spark ignitor module to turn gas to the fryer
OFF
if a burner
FLAME OUT
occurs.
4. A Drain Valve Safety Switch and a Default-to-Off circuit in the Default-to-Manual-Restart (DTMR) Control that will
DIS-
ABLE
the fryer each time the drain valve is
OPENED
.
5. An
AIR PRESSURE
switch to open the electrical circuit to the spark ignitor and gas valve which will turn the gas to the fryer
OFF
in the event the blower motor fails.
H. RATING PLATE:
Information on this plate includes the model and serial number; BTU/HR input rating of the burners; gas manifold pressure in
inches W.C. ; minimum inlet gas required, orifice size; and type of gas. This data is essential for proper identification when com-
nicating with ULTRAFRYER SYSTEMS or requesting special parts or information. The rating plate is located on the inside of the
Service Access door.
THE FRYER MUST BE CONNECTED ONLY TO THE TYPE OF GAS IDENTIFIED ON THIS RATING PLATE!
Figure (from left to right):
18” Model Par30 and 24” Model Par25
Содержание F-P-30-14
Страница 5: ...PN 30A170 rev Jan2008 5 GENERAL INFORMATION...
Страница 11: ...PN 30A170 rev Jan2008 11 PRE INSTALLATION...
Страница 13: ...PN 30A170 rev Jan2008 13 RECEIVING INSTALLING...
Страница 18: ...PN 30A170 rev Jan2008 18 INITIAL START UP...
Страница 20: ...PN 30A170 rev Jan2008 20 ABBREVIATED OPERATING INSTRUCTIONS...
Страница 23: ...PN 30A170 rev Jan2008 23 PREVENTIVE MAINTENANCE TROUBLESHOOTING...
Страница 26: ...PN 30A170 rev Jan2008 26 CLEANING...
Страница 28: ...PN 30A170 rev Jan2008 28 FILTER TUB ASSEMBLY INSTALLATION...
Страница 30: ...PN 30A170 rev Jan2008 30 TECHNICAL ASSISTANCE ORDERING INFORMATION...
Страница 32: ...PN 30A170 rev Jan2008 32 RECOMMENDED SPARE PARTS...
Страница 34: ...PN 30A170 rev Jan2008 34 PARTS IDENTIFICATION...
Страница 41: ...PN 30A170 rev Jan2008 41 WIRING DIAGRAMS...