PN 30A170 rev Jan2008
10
INLET GAS LINE REQUIREMENTS
PIPE
LENGTH
PIPE DIAMETERS (inches & (mm equivalents))
Maximum Allowable Flow (Shown in ft
3
/hr (M
3
/hr))
Feet
(Meters)
15
(4.6)
62
(1.7)
170
(4.7)
350
(9.8)
620
(17.4)
960
(26.9)
2,000
(56.0)
3,500
(98.0)
5,400
(151.2)
11,200
(313.6)
30
(9.1)
43
(1.2)
120
(3.4)
245
(6.9)
430
(12.0)
680
(19.0)
1,400
(39.2)
2,450
(68.6)
3,800
(106.4)
7,900
(221.2)
45
(13.7)
35
(1.0)
98
(2.7)
200
(5.6)
355
(9.9)
530
(14.8)
1,150
(32.2)
2,000
(56.0)
3,200
(89.6)
7,900
(182.0)
60
(18.3)
30
(0.8)
84
(2.4)
175
(4.9)
310
(8.7)
480
(13.4)
1,000
(28.0)
1,760
(49.3)
2,700
(75.6)
5,600
(156.8)
75
(22.9)
27
(0.8)
76
(2.1)
155
(4.3)
275
(7.7)
430
(12.0)
890
(24.9)
1,560
(43.7)
2,450
(68.6)
5,000
(140.0)
90
(27.4)
25
(0.7)
70
(2.0)
145
(4.1)
250
(7.0)
395
(11.1)
810
(22.7)
1,430
(40.0)
2,260
(63.3)
4,550
(127.4)
105
(32.0)
23
(0.6)
64
(1.8)
132
(3.7)
232
(6.5)
370
(10.4)
(750
(21.0)
1,300
(36.4)
2,100
(58.8)
4,200
(117.6)
120
(36.6)
21
(0.6)
60
(1.7)
125
(3.5)
215
(6.0)
340
(9.5)
700
(19.6)
1,200
(33.6)
1,950
(54.6)
4,000
(112.0)
150
(45.7)
19
(0.5)
54
(1.5)
110
(3.1)
195
(5.5)
310
(8.7)
630
(17.6)
1,080
(30.2)
1,750
(49.0)
3,550
(99.4)
180
(54.9)
17
(0.5)
49
(1.4)
100
(2.8)
175
(4.9)
280
(7.8)
570
(16.0)
960
(26.9)
1,600
(44.8)
3,200
(89.6)
210
(64.0)
16
(0.4)
44
(1.2)
94
(2.6)
165
(4.6)
260
(7.3)
530
(14.8)
890
(24.9)
1,450
(40.6)
3,000
(84.0)
240
(73.2)
15
(0.4)
43
(1.2)
88
(2.5)
155
(4.3)
240
(6.7)
500
(14.0)
840
(23.5)
1,350
(37.8)
2,800
(78.4)
270
(82.3)
14
(0.4)
40
(1.1)
83
(2.3)
145
(4.1)
230
(6.4)
470
(13.2)
780
(21.8)
1,300
(36.4)
2,650
(74.2)
300
(91.4)
14
(0.4)
38
(1.1)
79
(2.2)
138
(3.9)
215
(6.0)
440
(12.3)
750
(21.0)
1,250
(35.0)
2,500
(70.0)
450
(137.2)
11
(0.3)
31
(0.9)
64
(1.8)
112
(3.1)
176
(4.9)
360
(10.1)
630
(17.6)
1,000
(28.0)
2,050
(57.4)
600
(182.9)
10
(0.3)
27
(0.8)
56
(1.6)
97
(2.7)
152
(4.3)
315
(8.8)
530
(14.8)
860
(24.1)
1,750
(49.0)
NOTE:
1) FT3/HR (M3/HR) values may vary due to heating value and specific gravity of gas supplied by local companies.
2) To determine the inlet gas line diameter for the distance between the fryer and main gas regulator, locate the FT3/HR (M3/HR) of gas required for the fryer and
pipe length and read the pipe diameter on the top row. For example: a PAR30 fryer operating on
NATURAL GAS
requires 90 FT3/HR (2.5 M3/HR)
of gas at the fryer’s inlet gas manifold. If the fryer bank is located 60 feet from the building gas regulator, a 1” (25mm) diameter gas line
MUST
be installed
between the manifold and regulator.
1⁄2
"
(13 mm)
3⁄4
"
(19mm)
1
"
(25mm)
11⁄4
"
(32mm)
11⁄2
"
(38mm)
2
"
(51mm)
21⁄2
"
(64mm)
3
"
(76mm)
4
"
(102mm)
I. INLET GAS LINE SIZING:
The Table below is used to calculate the size (diameter) of the inlet gas line from the building regulator to the fryer manifold.
NUMBER
DESCRIPTION
RATING
BTU/HR (MJ/HR)
24322
3/4" (19mm) Diameter Flexible Gas Line (w/quick connect
couplings) 48" (1219mm) long. Connect-It SSGC75-48-UCQ
225,000 (238)
24323
1” (25mm) Diameter Flexible Gas Line (w/quick connect
couplings) 48" (1219mm) long. Connect-It SSGC100-48-UCQ
435,000 (459)
24456
1 1/4" (32mm) Diameter Flexible Gas Line (w/quick connect
couplings) 48” (1219mm) long. Connect-It SSGC125-48-UCQ
875,000 (924)
FLEXIBLE GAS LINES STOCKED BY ULTRAFRYER SYSTEMS
J. GAS LINES
The Flexible Gas Line used to connect the gas manifold to the building gas supply line must be rated for the BTU/Hr (MJ/Hr)
designated for the Fryer. Flexible gas lines and their ratings stocked by Ultrafryer Systems are listed below:
Содержание F-P-30-14
Страница 5: ...PN 30A170 rev Jan2008 5 GENERAL INFORMATION...
Страница 11: ...PN 30A170 rev Jan2008 11 PRE INSTALLATION...
Страница 13: ...PN 30A170 rev Jan2008 13 RECEIVING INSTALLING...
Страница 18: ...PN 30A170 rev Jan2008 18 INITIAL START UP...
Страница 20: ...PN 30A170 rev Jan2008 20 ABBREVIATED OPERATING INSTRUCTIONS...
Страница 23: ...PN 30A170 rev Jan2008 23 PREVENTIVE MAINTENANCE TROUBLESHOOTING...
Страница 26: ...PN 30A170 rev Jan2008 26 CLEANING...
Страница 28: ...PN 30A170 rev Jan2008 28 FILTER TUB ASSEMBLY INSTALLATION...
Страница 30: ...PN 30A170 rev Jan2008 30 TECHNICAL ASSISTANCE ORDERING INFORMATION...
Страница 32: ...PN 30A170 rev Jan2008 32 RECOMMENDED SPARE PARTS...
Страница 34: ...PN 30A170 rev Jan2008 34 PARTS IDENTIFICATION...
Страница 41: ...PN 30A170 rev Jan2008 41 WIRING DIAGRAMS...