SINGLE LEVER CONTROL B501 AND B502

E

N

G

L

IS

H

1.2 Dimensions

1  PRODUCT DESCRIPTION

1.1 Product description and recommendations for use

The  B501  single  engine  and  the  B502  dual  engine  controls  are  designed  as  a  single  lever  dual  function  per
engine.  They  are  specifically  designed  to  operate  with  outboard,  stern  drive  (I/O)  and  inbord  marine
propulsion  engines.  The  controls  can  operate  with  all  Ultraflex  cables  except  the  C4; 

K59  kit  is  included

with  both  the  controls,  necessary  to  install  Ultraflex  C2,  C8,  C0,  and  Mach  0  cables.

For  all  the  other  cables  the  following  kits  are  available  on  demand:

- K 60 for cables Ultraflex C5 - C16 - MACH 5;
- K 61 for cables Ultraflex C22;
- K 62 for cables Ultraflex C36 - MACH 36.
- The  cables  C14  and  MACH14  require  no  installation  kit.

The  pictures  below  show  the  lever  control  B501  and  B502  dimensions.

B501

B502

M

in

im

u

m

 

d

is

ta

n

c

e

to

 

a

ll

o

w

 

th

e

c

a

b

le

 

in

s

ta

ll

a

ti

o

n

M

in

im

u

m

 

d

is

ta

n

c

e

to

 

a

ll

o

w

 

th

e

c

a

b

le

 

in

s

ta

ll

a

ti

o

n

Содержание B 502

Страница 1: ...ONTROL Installationandmaintenancemanual ULTRAFLEX PARTNER R E N G L IS H Dr No 31859 a 04 10 2016 I UK F page 2 pag 21 page 41 IT A L IA N O F R A N A IS B 501 B 502 CH BH CHT BHT CHTL BHTL CH BH CHT...

Страница 2: ...processes starting from the design in order to ensure product quality to the customer maintain and improve the quality standards constantly pursue a continuous process improvement to meet the market n...

Страница 3: ...EXCEPT CHTL BHTL VERSION NOT INCLUDED 8 3 4 CONNECTING CONTROL CABLE 9 3 5 INSTALLATION OF CABLES C14 AND MACH 14 9 3 5 1 SHIFT CABLE CONNECTION 9 3 5 2 THROTTLE CABLE CONNECTION 11 3 6 ADJUSTING THE...

Страница 4: ...explains the meaning of some nautical words contained in this manual DANGER Immediate hazards which CAUSE severe personal injury or death WARNING CAUTION Operations which should be performed by qualif...

Страница 5: ...o 8A 16012 Busalla GE Italy Tel 39 010 962 0239 Italy Tel 39 010 962 0244 international Fax 39 010 962 0333 Email ut ultraflexgroup it www ultraflexgroup it North South Central America UFLEX USA 6442...

Страница 6: ...opulsion engines The controls can operate with all Ultraflex cables except the C4 K59 kit is included with both the controls necessary to install Ultraflex C2 C8 C0 and Mach 0 cables For all the other...

Страница 7: ...o check that all the components supplied with it are contained in the package refer to list If you identify any damage notify the carrier and your supplier WARNING Personnel handling the load must wor...

Страница 8: ...rd as shown in the picture 3 Extract the lever and turn it to the desired position then reinsert it by putting into gear with the shaft of the control box 3 2Controlboxinstallation 1 Install the contr...

Страница 9: ...able for each cable type K59 kit is also included with both single levers B501 and B502 To install the cables on the control controls follow the instructions provided with each kit To install the cabl...

Страница 10: ...ing to the stroke of the cable see the table below 5 Measure the engine shift lever stroke from the forward gear to the reverse gear See the possible strokes on the control device and select the neare...

Страница 11: ...ft cable stroke and make sure that is compliant with the following conditions WARNING During the shift engagement the lever movement must be always fluid with a constant resistance The lever must no b...

Страница 12: ...the hardening of the clutch or unscrew it to obtain a smoother movement To check the friction of the lever move it clockwise and counter clockwise ADJUSTING THE CLUTCH MUST BE PERFORMED WITH ENGINE TU...

Страница 13: ...iding unexepected movements of the boat To assemble it do as follows 2 Position the device 30 on plate 29 inserting the cylinder 31 inside the plastic guide 32 30 31 29 32 28 If you are installing the...

Страница 14: ...ISER and MARINER requires the use of Mercury solenoid kit and conductor complex WARNING In case of high inductive load we recommend to use a supporting relay in order to protect the switch CAUTION In...

Страница 15: ...on the lever hub and at the same time put the lever forward To unlock the B501 B502 control lever CHTL BHTL version from the neutral position pull the lock in neutral trigger located on the lower part...

Страница 16: ...not modify the system or add devices to it without written authorization or the intervention of an ULTRAFLEX technician describing the change made in the description of the work performed Do not use t...

Страница 17: ...nd tighten if necessary WARNING DANGER Loosening or separation of nuts holding the system in place can cause not only malfunctioning of the single lever control but damage or injury Periodically check...

Отзывы: