SINGLE LEVER CONTROL B501 AND B502
-
page 11
of 63
Installation and maintenance manual
ULTRAFLEX
E
N
G
L
IS
H
Adjust the shift cable stroke in order to not force the top and the bottom of the engine stroke.
The non-compliance with this recommendation causes the control system malfunction such as:
- High resistance to the lever operation
- Early wear of the mechanism that can cause its locking.
WARNING
7
Engage the rod
(14) on the pin (12)
8
Mount the plate
(15) in the way shown
in the picture and fix
it with the screw (16)
on the hole (17).
Check the right setting of shift cable stroke and make sure that is compliant with the following conditions.
WARNING
During the shift engagement, the lever movement must be always fluid with a constant resistance.
The lever must no become stiffer during the throttle engagement, otherwise check that the control shift
stroke corresponds to the engine one.
3.5.2 Throttle cable connection
14
12
16
15
17
1
Remove
the
cable
fastener (7) from the plate (8)
removing the screws (9).
4
Engage the rod
(19) on the pin (20).
3
Remount the cable
fastener (7) on the plate
(8) aligning the cable
cylinder (10) with the
hole of the cable
fastener.
Fix the cable fastener
to the plate with the
screws (9).
2
Mount the cable
making sure the
cable cylinder (10) is
placed inside the
plate hole (18).
7
8
9
10
7
8
9
18
10
20
19