9. Slide sensor down to the marks made before removing bad sensor DO NOT tighten zip
ties at this point
10. The light on the new sensor should turn on when it is in position
11. Check the input on the touch screen for a check mark
12.
If there isn’t a check mark start over at step 6
13. When there is a check mark tighten zip ties
UV sensor
1. Remove screw that holds bracket to cure tube
2. Disconnect signal cable
3. Remove screw that hold bracket to sensor box
4. Replace with new sensor box
5. Attach to cure tube
6. Return bad sensor and box to Ultra Optics
THERE IS A CORE CHARGE FOR THIS SENSOR AND BOX
Conveyor blocked sensor
1. Disconnect signal wire
2. Remove bad sensor from bracket
3. Attach new sensor
4. Do not adjust dials on this sensor
Water sensor
1. Turn off water
2. Disconnect power and signal cables to the sensor
3. Unscrew nut at base of sensor DO NOT REMOVE coupler from metal tee
4. Remove bad sensor
5. Install new sensor and hand tighten nut at base of sensor do not over tighten
6. Connect power and signal cables
7. Turn water on
Lift cylinder up and down sensor
1. Make a mark on the lift cylinder at the top and bottom of bad sensor
2. Disconnect signal cable from sensor
3. Loosen set screw on sensor
4. Slide bad sensor to the bottom of groove to remove bad sensor
5. Insert new sensor and slide into position between markings
6. Tighten set screw on sensor
7. Reconnect signal cable
Vacuum Sensor
1. Disconnect air tubes going into sensor
2. Disconnect signal cable
3. Connect signal cable to new sensor
4. Connect air tubes to new sensor
5. Program sensor as per instructions