ultra-hyperspike
MPA400-MAN-IPFORMER Rev B | Copyright © 2020 USSI
See cover page for export control
Page 18
Soft Reset
A soft reset restores all parameters except the network settings. To reset the device including network
settings perform a Hard Reset.
1) Connect to the web user interface of the MPA400 and navigate to the DEFAULTS tab.
2) Click on Reset Factory Defaults to perform a reset of the device.
Figure 14 - Defaults Page
Hard Reset
A hard reset restores all values and settings on the MPA400. To perform a hard reset:
1) Press the reset button located in the front panel of the device for approximately 10 seconds.
2) The green LED will flash 3 times to confirm reset operation.
3) Once the process is complete, the device will reboot.
4) The network settings will have been restored.
Note: The IP address may have changed, listen to the SonicIP® announced over the audio
output to verify IP address.