HyperSpike
®
LineWave Installation and Maintenance Manual
Copyright © Ultra Electronics
– USSI, Columbia City, IN 46725 USA
90243A-MAN-LINEWAVE Rev C
Page 4
1.3. Line Wave UL Directional Characteristics
90243A-801
90243A-802
90243A-803
90243A-804
HORIZONTAL
AXIS
-3Db Angle
+/- 35°
+/- 40°
+/- 40°
+/- 40°
-6Db Angle
+/- 65°
+/- 70°
+/- 70°
+/- 75°
SPL @ +/- 90°
86.2 dBA
90.8 dBA
95.2 dBA
98.2 dBA
VERTICAL
AXIS
-3Db Angle
+/- 35°
+/- 20°
+/- 10°
+/- 10°
-6Db Angle
+/- 65°
+/- 45°
+/- 25°
+/- 20°
SPL @ +/- 90°
86.2 dBA
88.2 dBA
89.3 dBA
88.3 dBA
1.4. LineWave Transformer Specifications
System
72575B-801
72542B-801
72542B-802
Type
Optional Transformer
Operation Mode
25 / 70 /100 Watt Tap Settings
Line Wave Compatibility
90243A-801/802
90243A-803
90243A-804
Maximum Power Draw:
30W
85W
170W
Maximum Supervisory Voltage:
25V/70V/100V Models
32V DC
Enclosure Material
Plastic
Ingress Protection
Indoor/Outdoor
Product Dimensions, HxWxD (in)
5.9 x 5.9 x 3.9
9.8 x 5.9 x 3.9
9.8 x 5.9 x 3.9
Net Weight
3lbs
4.5lbs
6.5lbs
2. Installation
LineWave speakers are by default configured as
4Ω, 8Ω, or 16Ω loudspeakers, however, an
optional line matching transformer is available if it is desired to connect the LineWave to a
Distributed Audio system. LineWave loudspeakers are approved for use with 25V, 70V, and
100V amplifiers. When configured for 25V, 70V, or 100V input, the LineWave includes a DC
blocking capacitor to facilitate DC speaker supervision.
All LineWave systems utilize an outdoor rated SJOOW cable for electrical connections. To
connect your LineWave speaker to an amplifier, route the cable to an appropriate junction box,
or other connector, as approved by local electrical codes and standards. For ease of
installation into a junction box, a Strain-Relief Cord Connector is included.
Note:
In the United States reference National Electrical Code (NFPA 70) and National Fire
Alarm and Signaling Code (NFPA 72) for installation standards.
Note:
In Canada reference CSA C22.1, Canadian Electrical Code, Part 1, Safety Standard for
Electrical Installations, Section 32, for installation standards.