3. 25V/70V/100V Power and SPL Specifications
Use the Power Draw and SPL Output tables in this section to select the LineWave model and
drive level appropriate for your application. Once a specific tap is selected, reference the
included wiring diagrams during installation.
3.1. 72575B-801 - Power Draw and Output SPL
Model Number
Input Voltage
RMS
Tap
Color
Power Draw,
Watts
dB SPL Max 1M,
A-Weighted
* dB SPL
Reverb @
10ft
* dB SPL
Anechoic
@ 3m
90243A-801
25V
Blue
0.5
86
72.4
78.2
25V
Orange
1.3
91
77.1
82.2
25V
Red
1.6
92
78.2
83.8
25V
Brown
2.7
94
79.9
85.3
70V
Blue
3.0
95
80.8
86.3
70V
Orange
8.3
100
84.9
90.7
70V
Red
10.7
101
85.9
91.9
70V
Brown
15.3
103
87.2
92.7
100V
Blue
5.7
98
83.5
89.1
100V
Orange
15.3
103
87.1
92.9
100V
Red
19.5
104
88.0
93.8
90243A-802
25V
Blue
0.8
92
75.8
81.9
25V
Orange
2.2
97
80.5
86.6
25V
Red
2.8
98
81.6
87.8
25V
Brown
4.1
100
83.2
89.4
70V
Blue
5.3
101
84.4
91.2
70V
Orange
14.9
106
88.6
94.6
70V
Red
19.3
107
89.5
95.6
70V
Brown
27.4
109
90.7
96.9
100V
Blue
10.3
104
87.1
92.9
100V
Orange
27.8
109
90.9
96.9
*UL Standard SPL Measurement