SPECIFICATIONS
Part Number:
4033730
Blower:
150 CFM @ 0.0" WG
140 CFM @ 0.2" WG
130 CFM @ 0.4" WG
Power:
580 Watts @ 80°F and 60% RH
Supply Voltage:
115 VAC – 1phase – 60 Hz
Current Draw:
5.1 Amps
Circuit Requirement:
15 Amps
Energy Factor:
2.4 L/kWh
Operating Range:
49°F Min, 95°F Max (Inlet Air Temperature)
Sized for:
Up to 1,800 Sq. Ft. - Typical
Water Removal at 80°F and 60% RH
Water Removal at 70°F and 60% RH
Capacity:
70 pints/day
Capacity:
47 pints/day
Efficiency:
5.0 Pints/kWh
Efficiency:
4.0 Pints/kWh
Duct Connections:
8" Round Inlet; 8" Round Outlet
Air Filter:
MERV-11, Mini Pleat
Efficiency:
65% ASHRAE Dust Spot
Size:
9" x 11" x 1"
Optional Air Filter:
MERV-14, Embossed Pleat (will need filter housing)
Efficiency:
95% ASHRAE Dust Spot
Size:
20" x 24" x 4"
Power Cord:
9', 115VAC, Ground
Drain Connection:
3/4" Threaded Female NPT
Refrigerant Type:
R410A (Refer to manufacturers label for more information)
Refrigerant Amount:
15 oz.
Dimensions:
Unit With Collars
Unit Without Collars
Shipping
Width:
12"
12"
15 5/8"
Height:
12"
12"
16"
Length:
28"
22"
31 5/8"
Weight:
55 lbs.
54 lbs.
65 lbs.
28"
With Collars Installed
22"
Without Collars Installed
12"
12"
Side View
Front View
Rear View
12"
12"
BACK
12”
12”
8"
8"
28”
22”
FRONT
12”
12”
8"
8"