VLS Service Manual - REV2015.04
Accessories
Page | 76
Accessories
Air Track
1. Ensure the air source (compressor) is OFF and disconnected from the system.
2. Power OFF and unplug the VLS system.
3. Open the Top Door.
4. Slide the X-axis arm toward the front of the system.
5. Remove the #2 mirror cover (1) by removing the thumbscrew (2), sliding the cover to the right and then
off the rail.
6. Locate and remove the screw securing the Y-Manifold together.
7. Locate and remove the 3 or 4 thumb screws (depending on the size of the system) holding the Air Track
to the Air Assist Receiving Brackets.
8. Carefully lift the Air Track out of the receiving brackets.
9. Installation is opposite of removal.
Air Assist Cone Alignment
1. Complete the
X-Axis Arm Alignment and Adjustment (Squaring)
.
2. Complete
3. Power ON the VLS and start the UCP.
4. Open the Top Door.
5. Using the arrows on the Viewer Tab of the UCP, position the focus carriage in the middle of the field.
6. Install the Air Assist Cone if not already installed.
7. Place a piece of paper underneath the cone and observe the position of the red beam in relation to the
center of the bottom of the cone.
8. If the red beam is not centered, make sure the cone is seated correctly. If necessary, slightly loosen (1/4
turn) the mounting screws for the cone base and adjust the base until the red diode laser comes out of
the center of the cone opening.
9. Tighten the base mounting screws gently and re-check the cone’s alignment.
Aligned
Misaligned
Содержание VLS Series