X-Axis
X-Axis Arm Replacement
NOTE:
Place any hardware removed from the laser machine in a safe place.
1. Power OFF and unplug the VLS.
2. Open the Top Door and bring the X-axis Arm forward.
3. Locate and unplug the Flex Cable on the right side of the arm connected to the Upper Flex Board near
the motor.
4. If air assist is installed, locate and remove the screw securing the Y-Manifold together.
X-Axis Motor
11. Disconnect the X-axis Motor wire from the Upper Flex Board.
12. Remove the 4 screws and washers that hold the motor to the motor bracket.
13. Remove motor and set apart.
14. Install the drive gear onto the new motor following steps 8 and 9 of X-Axis Drive Gear.
15. Attach the new motor to the motor mount with the 4 screws and washers removed in step 12.
16. Reinstall the motor mount onto the X-axis rail by attaching it with the two screws and two washers
removed in step 4. Ensure the X-axis belt loops around the drive gear correctly.
17. Tension the belt according to the steps outlined in
18. Square the arm following the steps outlined in the section
X-Axis Arm Check and Adjust (Squaring)
.