VLS Service Manual - REV2015.04
Adjustments and Settings
Page | 16
Adjustments and Settings
12. Use the Focus Tool to focus on the top of the flat part of the concave metal fixture. DO NOT focus on top
of the black metal cover that is located on the left side of the rotary.
13. When finished, click
Save
on the
Rotary Calibration
window.
14. When the
Confirmation
message displays, click
Yes
to accept the new values.
15. Click
Close
. The focus carriage will re-home automatically on exiting the window.
16. Calibration is complete.
X-Axis Arm Alignment Check and Adjustment (Squaring)
1. Power OFF the VLS and unplug it.
2. Remove the #2 mirror cover (1) by removing the thumbscrew (2), sliding the cover to the right and then
off the rail.
3. Pull the X-axis arm toward the front of the stage until it stops.
4. Observe if the left side and right side of the X-axis arm make contact with the left and right side
shoulder screws, at the same time, respectively.
5. If there is a gap between the shoulder screw and the contact point on either the left or right side of the
arm, square the arm by making the following Adjustments.