INSPECTION AND MAINTENANCE
6.3.1
General guidelines
ULMA is responsible for the delivery of the
products, for sale or rent, in good working
condition.
From the moment of delivery, the responsibility
for correct use, inspection and product
maintenance passes on to the purchaser or lessee.
All damaged and broken parts, parts with missing
components, i.e. all parts in no proper working
condition must be removed from service.
For use, inspection and maintenance of the
product, special attention should be paid to the
following points:
13.
Items aimed to ensure people´s safety
14.
Items made of aluminium, as they are more
vulnerable to damages of the welded joints and
deformation
6.3.2
Inspection instructions of lifting appliances
with CE marking of ULMA Construcción
Before each use, the condition of the lifting
appliance must be checked, confirming the good
working condition of the following parts:
SYSTEM PART
SPECIFICATION
Outer plate
Welded joints without fissures or
cracks
Ring
Without deflection nor excessive
wear
Hexagonal
bolt, nut and
washer
No missing components
Appropriate tightening of the
parts
Without deflection
ID plate
Existing and readable
In case that the lifting appliance does not fulfil all
defined requirements, it must be removed from
service.
For more information, consult ULMA Construcción.
6.3.3
Inspection instructions with CE marking of
equipment marketed by ULMA Construcción
Equipment with CE marking marketed by ULMA
Constucción is checked following the instructions
stipulated in the User´s Guide of the respective
product.