- 24 -
11.Setting the alarm preset values
Set the preset values on the upper and lower limits in alarm output.
The setting range is -999 - 9999.
Operation key
Indication
Procedure
M
A B C D
o u t 1
E F G H
9
9 9 9
Press the key for 2 seconds or more.
“
out1
”
appears in displays A-D and the preset
value setting for OUT1 is shown.
M
A B C D
o u t 2
E F G H
9 9 9 9
Changes the OUT number.
Each time the key is pressed, the OUT number
goes up by one.
(out1→out2→out3→out4→out1→・・・)
.
A B C D
o u t 2
E F G H
9
9
9 9
→ → →
Shifts the flashing indication to the digit to the
right.
Each time the key is pressed, shifts the
indication to one right.
∧
A B C D
o u t 2
E F G H
9
0
9 9
Changes the value of the flashing digit.
Each time the key is pressed, the number goes
up by one.
(0→1→・・・→9→0→・・・)
RES
After adjusting the setting, use this key to
register it. The display returns to the readings
following registration.
M + .
The display returns to the readings, without
registering.
When setting value has been changed by
mistake, use these keys.
Note 1:The decimal place of the reading is interlocked with Mode 00.
Note 2:Upon setting this mode, when pressing Up key during the setting of display
unit E, the next of 9 shows
“
-
”
display.(→9→-→0→)