Uhlenbrock digital Intelli Drive 2 Скачать руководство пользователя страница 9

Byte

 

Bit

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A /

 

From

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fahr.

 

Lok fährt

 

 

1

 

/

7

F1

 

F2

 

F3

 

F4

 

F0

 

n.b.

 

Fahr.

 

Vorw.

 

 

2

 

/

8

F5

 

F6

 

F7

 

F8

 

F9

 

F10

 

F11

 

F12

 

Vorw.

 

Driving direction 

forward

 

 

3

 

/

9

F13

 

F14

 

F15

 

F16

 

F17

 

F18

 

F19

 

F20

 

n.b.

 

unused

 

 

4

 

/ 10

F21

 

F22

 

F23

 

F24

 

F25

 

F26

 

F27

 

F28

 

 

 

 

5

 

/ 11

F29

 

F30

 

F31

 

F32

 

F33

 

F34

 

F35

 

F36

 

 

 

 

6

 

/ 12

F37

 

F38

 

F39

 

F40

 

F41

 

F42

 

F43

 

F44

 

 

 

 

  

The bits in the respective entries (bytes) 13 - 16 for the output have the following meaning:

 

 

Bit

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

Byte

 

 

 

 

 

 

 

 

 

13

 

A1

 

A2

 

 

 

 

 

 

 

14

 

A0v

 

A0h

 

S-CLK

 

S-Data

 

ABV

 

ABV2

 

ABV3

 

RG

 

 

15 

A0-P2  A1-P2  A2-P2

 

16

 

Cross  S-F22  S-F23  S-F24  S-F25  S-F26  S-F27  S-F28

 

 

A0v

 

Front light output

 

A0h

 

Rear light output

 

S-CLK

 

Output SUSI CLK: (enable A4 logic, CV50 bit4 = 1) or (enable servo1, CV166 bit0 = 1)

 

S-Data

 

Output SUSI Data: (enable A3 logic, CV50 Bit4 = 1) or (enable servo2, CV166 Bit0 = 1)

 

ABV

 

Starting and braking deceleration 1

 

ABV2

 

Starting, braking deceleration 2

 

ABV3

 

Starting, braking deceleration 3

 

RG

 

Rangiergang

 

A0-P2

 

Light outputs, 2nd dimming

 

A1-P2

 

Function out1, 2nd dimming

 

A2-P2

 

Function out2, 2nd dimming

 

Cross

 

CROSS-Bit für PWM-modulierte Ausgänge

 

S-F22 - S-F28 functions F22 - F28 on the SUSI interface on or off, depending on the result of the conditions set in bytes 1 

-  12.  The  state  of  these  functions,  as  it  is  transmitted  by  the  digital  control  center,  is  then  no  longer 
transferred to the SUSI interface.

 

 

The CV159 must be set accordingly for transfer of F22 - F28 to SUSI.

 

 

The CV number to be programmed is calculated from the

 

 

for lines 1 - 16

 

for lines 17 - 32

 

 

Base value 256

 

Base value 256

 

 

plus (line number minus 1) multiplied by 16

 

plus (line number minus 17) multiplied by 16

 

 

plus the number of the byte.

 

plus the number of the byte.

 

 

Formula:

 256 + (line - 1) * 16 + bytes

 

Formula:

 256 + (line - 17) * 16 + bytes

 

 

The bit structure and the values to be  programmed  accordingly in  the  CVs are comparable to the configuration CVs of the 
decoder. This means that there is a fixed value per bit set. If the bit is not set, the value for this bit remains 0.

 

 

Bit

 

Wert

Bit 0

 

1

Bit 1

 

2

Bit 2

 

4

Bit 3

 

8

Bit 4

 

16

Bit 5

 

32

Bit 6

 

64

Bit 7

 

128

Summe

 

255

 

The values for the individual CVs can now be derived from the above-mentioned information.

 

 

Examples:

 

 

The output

 A1 should

 be switched on

 when the function key

 F1 is

 switched on.

 

 

Bank 1, line 1 -> CV31 = 8, CV32 = 0

 

 

There are two CVs to program

 

 

First CV for the power condition (F1 on), second CV for the output (A1 on)

 

 

F1 key

 on

 -> CV number = 256 + (1 - 1) * 16 + 1 = 257

 

 

F1 key

 on

 -> byte 1, bit 0 = 1 -> CV 257 = 1

 

 

Output

 A1 switched on

 -> CV number = 256 + (1 - 1) * 16 + 13 = 269

 

 

Output

 A1 switched on

 -> byte 13, bit 0 = 1 -> CV269 = 1

 

 

The light output at the front (

A0v)

 should be switched on

 when the function key

 F0 is

 switched on

 and the

 locomotive is 

moving. Bank 1, line 2 -> CV31 = 8, CV32 = 0

 

There are two CVs to program

 

 

Key

 F0 on

 +

 drive -

> CV number = 256 + (2 - 1) * 16 +1 = 273

 

 

Key

 F0 on

 +

 drive -

> byte 1, bit 4 = 1 + bit 6 = 1-> CV 273 = 16 + 64 = 80

 

 

Output

 A0v switched on

 -> CV number = 256 + (2 - 1) * 16 + 14 = 286

 

 

Output

 A0v turned on

 -> byte 14, bit 0 = 1 -> CV286 = 1

 

 

The starting, braking deceleration 2 (ABV2) and the

 output

 A2 are to

 be switched on

 when the locomotive

 moves 

forward (previous) (driving), not

 stationary and

 the function F6 is switched on.

 

 

Bank 1, line 3 -> CV31 = 8, CV32 = 0

 

 

There are four CVs to program

 

 

Fahr. + Vorw.

 -> CV-Nummer = 256 + (3 - 1) * 16 +1 = 289

 

 

Fahr. + Vorw.

 -> Byte 1, Bit 6 = 1 + Bit 7 = 1-> CV 289 = 64 + 128 = 192

 

 

Key F6 on

 ->

 CV number = 256 + (3 - 1) * 16 +2 = 290

 

 

Key

 F6 switched on

 -> byte 2, bit 1 = 1 -> CV 290 = 2

 

 

A2 switched on

 -> CV number = 256 + (3 - 1) * 16 + 13 = 301

 

 

A2 switched on

 -> byte 13, bit 1 = 1 -> CV301 = 2

 

 

ABV2 switched on

 -> CV number = 256 + (3 - 1) * 16 + 14 = 302

 

 

ABV2 turned on

 -> byte 14, bit 5 = 1 -> CV302 = 32

 

 

.

 

.

 

.

 

Содержание Intelli Drive 2

Страница 1: ...g track 8 Power consumption right red when the programming mode of the control panel is called up When reading or programming very small currents usually flow which do not damage the decoder in the ev...

Страница 2: ...de de_DE service download konformit tserkl rung index htm Our advantages for you If you have any questions we are here for you Internet FAQs can be found at www uhlenbrock de E Mail service uhlenbrock...

Страница 3: ...tion outputs A1 A2 in the user manual do not apply to the decoder 73115 with 6 pin NEM 651 interface Analog operation with DC voltage The locomotive decoder is suitable for analog operation with DC vo...

Страница 4: ...teps via CV 2 CV 5 and CV 6 0 Use characteristic curve from CV 67 94 16 5 Kurze Adresse CV 1 Register 1 0 Long address CV 17 and 18 32 Bit Konfiguration CV 50 Wert 0 Do not use Motorola 2nd address 0...

Страница 5: ...1st edition of this description remains valid If braking is initiated with a constant braking distance the decoder only responds to driving commands again when the locomotive has come to a standstill...

Страница 6: ...If such an output is switched on via a wireless button it is automatically switched off in the desired direction of travel CV113 2 A1 forward from CV113 4 A2 forward from CV113 8 A3 forward from CV113...

Страница 7: ...switch off automatically after an adjustable time without having to switch off the function key Furthermore the decoder can ensure that the coupling is only actuated for a short switch on moment with...

Страница 8: ...veral outputs starting and braking delays shunting second dimming of the function outputs SUSI as logic level output transfer of the function keys F22 to F28 to SUSI as well as the setting of the CROS...

Страница 9: ...la 256 line 1 16 bytes Formula 256 line 17 16 bytes The bit structure and the values to be programmed accordingly in the CVs are comparable to the configuration CVs of the decoder This means that ther...

Страница 10: ...CV 272 1 To facilitate programming especially for extended function mapping the programming software Lok Tool can be used which is included with the digital programming and test station DigiTest from...

Страница 11: ...From decoder software version 23 CV7 3rd edition 25 02 19...

Страница 12: ...ecoders Programming with a M rklin control unit eg 6021 With a M rklin control panel all CVs can be programmed but not read out The decoder can be put into programming mode in two ways a and b dependi...

Страница 13: ...255 255 Bit 0 0 DC analog operation direct current off 0 Bit 0 1 DC analog operation direct current on 1 Bit 2 0 Data format DCC from 0 Bit 2 1 Data format DCC a 4 Bit 3 0 Data format Motorola from 0...

Страница 14: ...ht A1 and A2 156Hz 0 Bit 3 1 Frequency light A1 and A2 24KHz 8 Bit 4 0 SUSI SUSI 0 Bit 4 1 SUSI A3 A4 output function mapping table 16 51 Decoder Konfiguration 2 Wert 0 135 3 131 Bit 0 0 Motor control...

Страница 15: ...value 200ms 16 240 131 Dynamic smoke generator control load threshold 0 255 5 132 Dynamic smoke generator control PWM normal operation 0 63 16 133 Dynamic smoke generator control PWM idle stand 0 63...

Страница 16: ...164 Servo control Servo 2 position 2 function key on 0 255 200...

Страница 17: ...es Switching on effect of light and function outputs A1 A2 0 7 0 bit 0 2 A0 to A2 Bit 0 effect off bit 1 effect on 189 Neon tubes turn on effect flash time value 5ms 0 255 20 190 Neon tubes turn on ef...

Страница 18: ...16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each until 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 320 3 8 16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 3...

Отзывы: