Uhlenbrock digital Intelli Drive 2 Скачать руководство пользователя страница 14

 

CV

 

Description

 

 

Value range

 

Value ex works

 

31

 

Pointer CV for CV banks

 

 

0,1,8

 

0

 

32

 

2nd pointer CV for CV banks

 

 

0, 1, 3, 4, 5,

 

255

 

 

 

 

 

255

 

 

33-46

 

Simple function mapping

 

 

0-255

 

 

 

Assignment of the function outputs to the CVs

 

 

 

 

 

CV 33

 

Light function button (F0) when driving forward

 

 

 

1

 

 

CV 34

 

Light function key (F0) when reversing

 

 

 

2

 

 

CV 35

 

Function key F1

 

 

 

4

 

 

CV 36

 

Function key F2

 

 

 

8

 

 

CV 37

 

Function key F3

 

 

 

16

 

 

CV 38

 

Function key F4

 

 

 

32

 

 

CV 39

 

Function key F5

 

 

 

64

 

 

CV 40

 

Function key F6

 

 

 

128

 

 

CV 41

 

Function key F7

 

 

 

0

 

 

CV 42

 

Function key F8

 

 

 

0

 

 

CV 43

 

Function key F9

 

 

 

0

 

 

CV 44

 

Function key F10

 

 

 

0

 

 

CV 45

 

Function key F11

 

 

 

0

 

 

CV 46

 

Function key F12

 

 

 

0

 

 

Assignment of the individual bits

 

Wert

 

 

 

 

Bit 0

 

Front light output

 

1

 

 

 

 

Bit 1

 

Rear light output

 

2

 

 

 

 

Bit 2

 

Function output A1

 

4

 

 

 

 

Bit 3

 

Function output A2

 

8

 

 

 

 

Bit 4

 

Function output A3 (SUSI/logic)

 

16

 

 

 

 

Bit 5

 

Function output A4 (SUSI/logic)

 

32

 

 

 

 

Bit 6

 

Rangiergang

 

64

 

 

 

 

Bit 7

 

Starting/braking deceleration

 

128

 

 

 

47

 

Motorola 1st trinary address (directly

 only with Motorola programming method)

 

0-255

 

12

 

48

 

Motorola 2nd trinary address (only

 with Motorola programming method)

 

 

0-255

 

0

 

49

 

Motorola 3rd trinary address (only

 with Motorola programming method)

 

 

0-255

 

0

 

50

 

Decoder Konfiguration 1

 

Wert

 

0-63

 

0

 

 

Bit 0=0

 

Do not use Motorola 2nd address

 

0*

 

 

 

 

Bit 0=1

 

Motorola 2nd address use

 

1

 

 

 

 

Bit 1=0

 

Do not use Motorola 3rd address

 

0*

 

 

 

 

Bit 1=1

 

Motorola 3rd address use

 

2

 

 

 

 

Bit 2=0

 

Do not replace light outputs

 

0*

 

 

 

 

Bit 2=1

 

Replace light outputs

 

4

 

 

 

 

Bit 3=0

 

Frequency light, A1 and A2 = 156Hz

 

0*

 

 

 

 

Bit 3=1

 

Frequency light, A1 and A2 = 24KHz

 

8

 

 

 

 

Bit 4=0

 

SUSI = SUSI

 

0*

 

 

 

 

Bit 4=1

 

SUSI = A3/A4 output function mapping table

 

16

 

 

 

51

 

Decoder Konfiguration 2

 

Wert

 

0-135

 

3, 131

 

 

Bit 0=0

 

Motor control from

 

0

 

 

 

 

Bit 0=1

 

Motor control a

 

1*

 

 

 

 

Bit 1=0

 

Motor control PID - Controller

 

0

 

 

 

 

Bit 1=1

 

Motor control SX - controller

 

2*

 

 

 

 

Bit 2=0

 

no dynamic period of motor control

 

0

 

 

 

 

Bit 2=1

 

Dynamic period of motor control

 

4

 

 

 

 

Bit 7=0

 

Light, A1/A2 PluX12 decoder (73145)

 

0

 

 

 

 

Bit 7=1

 

Light, A1/A2 cable/NEM decoder (not 73145)

 

128

 

 

 

53

 

Period of motor control in 100µs steps

 

 

0-255

 

40

 

54

 

Motor control P-constant of the PID controller

 

 

0-255

 

100

 

55

 

Motor control I-constant of the PID controller

 

 

0-255

 

40

 

56

 

Motor control D-constant of the PID controller

 

 

0-255

 

32

 

57

 

Regler Offset

 

 

 

0-255

 

6

 

58

 

Measuring gap for EMF measurement in 100µs steps

 

 

0-255

 

8

 

59

 

Factory reset

 (also possible via CV8)

 

 

0-4

 

0

 

 

1 = CV 0 - 256, and CV257 - 512 (RailCom® Bank 7)

 

 

 

 

 

2 = CV 257 - 512 (RailCom Plus

®

 Banken 5 & 6)

 

 

 

 

 

3 = CV 257 - 512 (extended function mapping banks 1 & 2)

 

 

 

 

 

4 = CV 257 - 512 (PWM modulation function outputs banks 3 & 4)

 

 

 

 

60

 

Short-circuit monitoring Motor, function outputs, temperature control.

 

-

 

-

 

 

Switched on (do not change)

 

 

 

 

61

 

Constant for the temperature shutdown

 

 

-

 

-

 

62

 

Constant of short-circuit detection of the FKT outputs (do not change)

 

 

-

 

-

 

63

 

Constant of short-circuit detection of motor output (do not change)

 

 

-

 

-

 

64

 

Page Register

 

 

0-255

 

0

 

 

for CV programming with a Motorola control unit

 

 

 

 

65

 

Offset-Register

 

 

0-255

 

0

 

 

for CV programming with a Motorola control unit

 

 

 

 

66

 

Speed correction forward

 

 

0-255

 

0

 

67-94

 

Extended speed step characteristic curve for speed steps 1 - 28

 

 

0-255 each

 

under.

 

95

 

Reverse speed correction

 

 

0-255

 

0

 

Содержание Intelli Drive 2

Страница 1: ...g track 8 Power consumption right red when the programming mode of the control panel is called up When reading or programming very small currents usually flow which do not damage the decoder in the ev...

Страница 2: ...de de_DE service download konformit tserkl rung index htm Our advantages for you If you have any questions we are here for you Internet FAQs can be found at www uhlenbrock de E Mail service uhlenbrock...

Страница 3: ...tion outputs A1 A2 in the user manual do not apply to the decoder 73115 with 6 pin NEM 651 interface Analog operation with DC voltage The locomotive decoder is suitable for analog operation with DC vo...

Страница 4: ...teps via CV 2 CV 5 and CV 6 0 Use characteristic curve from CV 67 94 16 5 Kurze Adresse CV 1 Register 1 0 Long address CV 17 and 18 32 Bit Konfiguration CV 50 Wert 0 Do not use Motorola 2nd address 0...

Страница 5: ...1st edition of this description remains valid If braking is initiated with a constant braking distance the decoder only responds to driving commands again when the locomotive has come to a standstill...

Страница 6: ...If such an output is switched on via a wireless button it is automatically switched off in the desired direction of travel CV113 2 A1 forward from CV113 4 A2 forward from CV113 8 A3 forward from CV113...

Страница 7: ...switch off automatically after an adjustable time without having to switch off the function key Furthermore the decoder can ensure that the coupling is only actuated for a short switch on moment with...

Страница 8: ...veral outputs starting and braking delays shunting second dimming of the function outputs SUSI as logic level output transfer of the function keys F22 to F28 to SUSI as well as the setting of the CROS...

Страница 9: ...la 256 line 1 16 bytes Formula 256 line 17 16 bytes The bit structure and the values to be programmed accordingly in the CVs are comparable to the configuration CVs of the decoder This means that ther...

Страница 10: ...CV 272 1 To facilitate programming especially for extended function mapping the programming software Lok Tool can be used which is included with the digital programming and test station DigiTest from...

Страница 11: ...From decoder software version 23 CV7 3rd edition 25 02 19...

Страница 12: ...ecoders Programming with a M rklin control unit eg 6021 With a M rklin control panel all CVs can be programmed but not read out The decoder can be put into programming mode in two ways a and b dependi...

Страница 13: ...255 255 Bit 0 0 DC analog operation direct current off 0 Bit 0 1 DC analog operation direct current on 1 Bit 2 0 Data format DCC from 0 Bit 2 1 Data format DCC a 4 Bit 3 0 Data format Motorola from 0...

Страница 14: ...ht A1 and A2 156Hz 0 Bit 3 1 Frequency light A1 and A2 24KHz 8 Bit 4 0 SUSI SUSI 0 Bit 4 1 SUSI A3 A4 output function mapping table 16 51 Decoder Konfiguration 2 Wert 0 135 3 131 Bit 0 0 Motor control...

Страница 15: ...value 200ms 16 240 131 Dynamic smoke generator control load threshold 0 255 5 132 Dynamic smoke generator control PWM normal operation 0 63 16 133 Dynamic smoke generator control PWM idle stand 0 63...

Страница 16: ...164 Servo control Servo 2 position 2 function key on 0 255 200...

Страница 17: ...es Switching on effect of light and function outputs A1 A2 0 7 0 bit 0 2 A0 to A2 Bit 0 effect off bit 1 effect on 189 Neon tubes turn on effect flash time value 5ms 0 255 20 190 Neon tubes turn on ef...

Страница 18: ...16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each until 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 320 3 8 16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 3...

Отзывы: