7. 4. 6  ASSEMBLY

1

Slide the drip tray into place..

2

Lubricate the tap piston, the hexagonal joint and the mixer

at the points indicated in figure 16, using only the grease that

came with the machine or other grease for use with food.

figure 16

3

Reassemble the tap on the container in reverse order

compared to that shown in figure 12.

4

Replace the container gasket.

N.B. the rim with the greater diameter must be rested on the

rear wall (see figure 17).

figure 17

5

Reassemble the hexagonal joint and then the mixer (see

figure 18).

figure 18

6

Replace the container by pushing it towards the back wall,

making sure it fits properly onto the gasket. The locking lever

will be lowered until it rests on the drip tray surface (see figure

19).

figure 19

7

Rinse using a cool beverage in order to eliminate any

remaining sanitising solution from the bottom of the containers.

Dry the inside of the containers with a disposable paper towel.

7. 5  IN-PLACE SANITIZATION

Sanitising the assembled device, prior to putting into

service, should only be performed, if necessary, as an

a d d i t i o n a l  p r e c a u t i o n   t o   t h e   s an i t i s a t i o n   o f  t h e

disassembled devices described previously, never instead

of it.

1

Prepare a solution of water and sanitising product approved

by the authorities in your country in a basin, according to the

manufacturer's specifications. In the absence of a specific

sanitising product, prepare a solution of water and sodium

hypochlorite (bleach) at a ratio of 1 tablespoon per 2 litres of

water.

2

Pour the solution into the containers.

3

Using a suitable brush, wipe the solution onto all parts

above the level of the solution and on the underside of the lid.

4

Install the lid and operate the dispenser in order to allow the

solution to be stirred for about 2 minutes. Drain the sanitising

solution from the containers through the taps and then dispose

of it.

5

Rinse using a cool beverage in order to eliminate any

Содержание MINIGEL 1

Страница 1: ...MANUALE D ISTRUZIONE OPERATOR S MANUAL CARNET D INSTRUCTIONS GEBRAUCHSANWEISUNG MANUAL DE INSTRUCCIONES ...

Страница 2: ...Marca UGOLINI S p A Fabricante UGOLINI S p A Modelo MiniGEL 1 2 3 PLUS 230V 50Hz responden con las siguientes Normativas En cumplimiento de las Normas 2006 42 CE 2014 30 CE 2014 35 CE EN ISO 12100 1 2010 EN ISO 12100 2 2010 EN60335 1 2012 A11 2014 EN60335 2 24 2010 EN60335 2 75 2004 A1 2005 A11 2006 A2 2008 A12 2010 EN62233 2008 11 EN62233 2009 04 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1...

Страница 3: ...r toxic liquids to the appliance 3 TECHNICAL CHARACTERISTICS We reserve the right to amend this manual without notice 4 INTRODUCTION Read this instruction booklet carefully in order to familiarise yourself with all aspects of the dispenser Like all mechanical products this machine will require cleaning and maintenance Good operation can also be affected by any errors made by the operator during di...

Страница 4: ...ontainer and only pour it into the machine containers after making sure that it is homogeneous and that the powder is well dissolved 6 Using the controls see Chapter 7 1 DESCRIPTION OF CONTROLS 7 The dispenser must operate without interruption the cooling system for each container will automatically stop when the product is ready to be dispensed maintaining the set density The mixing devices will ...

Страница 5: ...an be locked to prevent access to the dispenser commands To do this hold down keys E and H at the same time for two seconds A keyboard lock is signalled by the display blinking the T symbol appearing together with the BLOC writing on the display All the controls are locked at this point To unlock the keypad hold down again keys E and H for three seconds The unlock is shown when the display flashes...

Страница 6: ... viously be enabled for the operation by set ting the regulation parameter PA09 to ON To perform this operation do as follows Start the machine in Service Mode by enabling the main switch and keeping pressed key A Press keys C and D at the same time to display the Para meter Regulation Mode PA01 appears on the display Press key C several times until parameter PA09 is di splayed Press key A to enab...

Страница 7: ...ITCH to OFF 7 4 1 DISASSEMBLING THE RECOVER OP TIONAL 1 Place the right hand part of the recover on a surface Place the container inside it see figure 2 see figure 3 figure 2 figure 3 2 Put the left hand part of the recover into position and make sure that it fits into the illustrated groove Click the two parts together see figure 4 see figure 5 figure 4 figure 5 7 4 2 DISASSEMBLY 1 To remove the ...

Страница 8: ...out of the evaporator cylinder Then remove the hexagonal joint see figure 9 figure 9 4 Remove the gasket from its housing see figure 10 figure 10 5 Disassemble the tap by following the order given see figure 11 figure 11 6 Remove the drip tray and empty it 7 Remove the flow restrictor from the container see figure ...

Страница 9: ...asin according to the manufacturer s specifications In the absence of a specific sanitising product prepare a solution of water and sodium hypochlorite bleach at a ratio of 1 tablespoon per 2 litres of water 3 Immerse all parts to be sanitised in the solution for the time indicated by the product manufacturer 4 Allow the sanitised parts to air dry on a clean surface 5 Dry the external parts of the...

Страница 10: ...e containers Dry the inside of the containers with a disposable paper towel 7 5 IN PLACE SANITIZATION Sanitising the assembled device prior to putting into service should only be performed if necessary as an additional precaution to the sanitisation of the disassembled devices described previously never instead of it 1 Prepare a solution of water and sanitising product approved by the authorities ...

Страница 11: ...all for service 5 In case of failure unplug the machine because unexpected start again would be possible 6 It needs to fix everything back in the initial position after any repairmen like screws and covers 8 1 MAINTENANCE TO BE CARRIED OUT BY QUALIFIED SERVICE PERSONNEL ONLY 1 Annually Remove all the panels and clean the inside of the machine including the base and the inside of the panels Never r...

Отзывы: